SONIC START® Streamline?0 pages
SONIC START® STREAMLINE™
50% Fewer Vacuum Tubing
Connection Fittings
SONIC START® STREAMLINE™ Eliminates Routine Maintenance
The clean and simplified SONIC START® STREAMLINE™ Prime Sensing System relocates the solenoid valve,
eliminates the vapor filter and frees 50% of the original fitting connection points for an improved priming system.
What’s the difference between the SONIC START® and the SONIC START® STREAMLINE™ ? Plenty!
A Detailed Look at the Improved System
Quick Disconnect Male Fitting
Vacuum Pump
Piping Arrangement
No solenoid valve located
here or at the control panel.
Quick Disconnect
90° Elbow
Improved with circular uniform constriction fit,
eliminating tubing gouges.
Improved with circular uniform constriction
fit, eliminating tubing gouges.
SONIC START® STREAMLINE™
Vacuum Dome Assembly
Relocating the 2-way solenoid valve to the
top of the vacuum dome takes sewage pump
pressure off of the vacuum tubing and tubing
fittings, which stops liquid and
debris from going beyond the vacuum dome.
This eliminates routine cleaning of the solenoid
valve and the vapor filter.
A new, faster 200 millisecond
SONIC START® Probe.
Delay Timer
Delays solenoid valve after power surge
or power loss to prevent over-priming.
Vacuum Release Valve
Located at the volute’s gauge port,
in case access to the solenoid or
inside of the vacuum dome is
required, vacuum is released here.
O n l i n e : s m i t h a n d l o v e l e s s .com • Phone: 913.888.5201 • FAX: 913.888.2173
Bulletin No. 621 ©2011 Smith & Loveless Inc.
SONIC START® Probe
"