Single-phase smoothing chokes0 pages
Gross prices! +43(0) 2689 2744-20 +43(0) 2689 2744-9 info@trafomodern.com www.trafomodern.com
Designed and tested according to:
• IEC/EN 61558-2-20
• VDE 0570-2-20
Typical applications:
• Power conversion
Basic equipment:
• Insulation class B
• Ambient temperature –25 to 40°C
• Connection terminal (<63 A)
• Frequency 50/60 Hz
Further equipment:
• Temperature control.....page 55
44
Chokes
Single-phase smoothing chokes DEG
Ws A Euro PU
Energy value
L x I2
Price1) of
currents up to
Type
Order no.
Price
per unit
Discount
category
Cu-factor2)
0.19
0.38
0.64
1
1.3
1.6
2
2.5
3.2
4
5.1
6.4
8.3
10.2
12.7
15.9
19.1
25.5
16
25
DEG0,03(*MH/*A)
206999
DEG0,06(*MH/*A)
207001
DEG0,1(*MH/*A)
207002
DEG0,16(*MH/*A)
207003
DEG0,2(*MH/*A)
207004
DEG0,25(*MH/*A)
207005
DEG0,315(*MH/*A)
207006
DEG0,4(*MH/*A)
207007
DEG0,5(*MH/*A)
207008
DEG0,63(*MH/*A)
207010
DEG0,8(*MH/*A)
207011
DEG1,0(*MH/*A)
207012
DEG1,3(*MH/*A)
207013
DEG1,6(*MH/*A)
207014
DEG2,0(*MH/*A)
207015
DEG2,5(*MH/*A)
207016
DEG3,0(*MH/*A)
207017
DEG4,0(*MH/*A)
207018
44.40
48.70
53.50
59.30
69.90
74.10
89.40
93.10
103.00
119.00
133.00
160.00
188.00
278.00
297.00
320.00
587.00
659.00
1 unit
56
0.15
0.50
0.60
0.60
1.00
1.00
1.30
1.30
1.50
2.00
2.30
3.00
4.00
4.50
5.50
5.50
8.00
10.40
Formula for the calculation of the energy value:
W=LxI2
L=inductivity [H]
I=current [A]
For the exact design of the choke the following
information must be added to the type
designation:
DEG0,16(*MH/*A)
Replace the asterisk in front of MH with the value
of the inductivity and the asterisk in front of A
with the current.
Sample order
• requested inductivity 25 mH
• rated current 5.9 A
• calculated energy value according to formula
0.87 Ws type DEG0,16
The correct type designation reads
DEG0,16(25MH/5,9A)
1) Excess charge for increased current on request
2) Additional material cost –› page 61