Single-phase autotransformers0 pages
Gross prices! · phone +43 / 26 89 / 27 44 - 0 · fax +43 / 26 89 / 27 44 - 9 · info@trafomodern.com · www.trafomodern.com Gross prices! · phone +43 / 26 89 / 27 44 - 18 0 · fax +43 / 26 89 / 27 44 - 9 · info@trafomodern.com · www.trafomodern.com
ETSP
Designed and tested according to
· IEC/EN 61558-2-13
· VDE 0570-2-13
· EN 60076-1
· UL 506
· CSA 22.2 No. 66
Typical applications
· Cost-efficient solutions
for voltage adjustment
Basic equipment
· Insulation class B / F from 6.3 kVA
· Ambient temperature –25 to 40 °C
· Connection terminal (<63 A)
· Frequency 50/60 Hz
Further equipment
· Enclosure IP23 page 56
· Additional tapping page 59
· Additional winding page 61
· Static shield winding page 59
· Temperature Control page 61
· Tropics resistant equipment page 59
19
Transformers
Single-phase autotransformers
Transformers
Single-phase autotransformers ETSP
4)
B kVA F kVA V (selectable) V (selectable) Euro A
0.03 - 50–1000 12–1000 ETSP0,03(*/*) 36.40 25 0.12
0.06 - ETSP0,06(*/*) 38.80 0.20
0.1 - ETSP0,1(*/*) 44.90 0.37
0.16 - ETSP0,16(*/*) 56.80 0.45
0.2 - ETSP0,2(*/*) 64.00 63 0.55
0.25 - ETSP0,25(*/*) 70.30 0.70
0.315 - ETSP0,315(*/*) 78.70 0.85
0.4 - ETSP0,4(*/*) 87.70 1.10
0.5 - ETSP0,5(*/*) 95.60 1.10
0.63 - ETSP0,63(*/*) 114.70 1.35
0.8 - ETSP0,8(*/*) 128.50 2.20
1 - ETSP1,0(*/*) 142.30 2.20
1.3 - ETSP1,3(*/*) 181.60 2.45
1.6 - 24–1000 ETSP1,6(*/*) 248.50 3.90
2 - ETSP2,0(*/*) 292.00 100 3.80
2.5 - ETSP2,5(*/*) 348.30 6.80
3 - ETSP3,0(*/*) 475.70 6.00
4 - ETSP4,0(*/*) 569.20 9.90
5 - 60–1000 ETSP5,0(*/*) 630.80 10.20
6.3 8 ETSP6,3(*/*) 810.10 100 12.00
8 10 ETSP8,0(*/*) 1,038.30 18.80
10 13 ETSP10,0(*/*) 1,301.30 200 23.00
13 16 ETSP13,0(*/*) 1,566.40 25.00
Rated power for use according
to insulation class1)
Rated input
voltage
Rated output
voltage
Type Price2)
per unit
Price2) for
currents up to
Cu-factor3)
B kVA F kVA V (selectable) V (selectable) Euro A
16 20 50–1000 60–1000 ETSP16,0(*/*) 1,753.30 26.00
20 25 ETSP20,0(*/*) 2,040.80 320 36.50
25 32 ETSP25,0(*/*) 2,558.10 44.20
Type rating for use according
to insulation class
Rated input
voltage
Rated output
voltage
Typ Price
per unit
Price for
currents up to
Cu-factor1)
• For versions with increased climate-resistance,
the transformer is supplied with a
specially insulated finish. The finish
enables the transformer to be used in
areas of high humidity
• UL/CSA only up to 600 V (incl. tapping)
When ordering, the following information
must be added to the type designation:
ETSP25(*/*)
1st place holder ^= rated input voltage
2nd place holder ^= rated output voltage
Sample order
• required throughput rating: 55 kVA
• requested rated input voltage 400 V
• requested output voltage 230 V
Notes for selection
ST = SN · (1 - lower voltage )
= 55 kVA (1 - 230 V/400 V) = 23.4 kVA
ST = Type rated power = power, which is
relevant for the size of the transformer
SN = Throughput power = Nominal power,
which is the relevant figure of the load of
the transformer
• The type rated power is always smaller
than the throughput rating.
• Versions with delta stabilizing winding on
request.
The correct type designation reads
ETSP25(400/230)
The unambiguous article number of your
configuration will be defined by trafomodern
during the offer- and order process.
Higher outputs on request.
1) Rated output when used according to
insulation class B, maximum of 130° C in
the core; for insulation class F maximum
of 155° C in the core.
2) Excess charge for increased current
–› page 58
3) Material surcharge –› page 64
4) Only on request
Typ No-load a b b1
losses
Shortcircuit
losses1
Shortcircuit
voltage
Efficiency
factor
c c1 e f ø g
Fig3
ETSP6,3
ETSP8
ETSP10
ETSP13
ETSP16
ETSP20
ETSP25
40
55
67
80
95
106
134
52
77
82
115
182
147
187
130
215
130
150
130
190
180
*)
*)
*)
*)
*)
*)
*)
0.97
0.97
0.98
0.98
0.98
0.98
0.99
260
260
320
320
320
370
370
185
215
195
225
255
240
270
152
182
172
202
232
220
250
400
400
450
450
450
510
510
310
310
360
360
360
430
430
230
230
270
270
270
320
320
126
156
142
172
202
190
220
10 x 18
10 x 18
13 x 20
13 x 20
13 x 20
13 x 20
13 x 20
kg W W %
Total
weight
Type No-load a b c
losses
Shortcircuit
losses1
Shortcircuit
voltage
Efficiency
factor
b c b c b c b c e f ø g b1 c1
Fig1
ETSP0,03
ETSP0,06
ETSP0,1
ETSP0,16
ETSP0,2
ETSP0,25
ETSP0,315
ETSP0,4
ETSP0,5
ETSP0,63
ETSP0,8
ETSP1,0
ETSP1,3
ETSP1,6
ETSP2,0
Fig2
ETSP2,5
ETSP3,0
ETSP4,0
ETSP5,0
0.7
0.8
1.5
2.0
2.3
3.0
3.8
4.3
5.2
6.8
7.7
9.6
13.4
14.9
20.0
21
26
32
35
4568
10
10
10
12
16
19
27
35
46
40
51
23
28
36
46
479
10
10
15
15
19
19
19
26
29
29
30
35
71
77
74
101
*)
*)
*)
*)
*)
*)
*)
*)
*)
*)
*)
*)
*)
*)
*)
*)
*)
*)
*)
0.79
0.83
0.87
0.90
0.91
0.91
0.93
0.93
0.93
0.94
0.94
0.94
0.95
0.96
0.96
0.96
0.97
0.97
0.97
66
66
85
85
85
106
106
121
121
121
151
151
151
175
175
230
230
230
230
62
74
68
82
91
82
90
88
121
141
107
124
150
138
200
185
210
225
235
80
80
91
91
91
112
112
119
133
133
211
211
211
240
157
255
255
255
255
62
74
68
82
91
82
90
88
100
120
107
145
171
138
168
215
240
210
235
80
80
91
91
91
112
112
119
119
119
145
159
159
240
240
275
275
255
255
62
74
68
82
91
82
90
88
100
120
107
124
150
159
190
160
240
255
265
80
80
91
91
91
112
112
119
119
119
145
145
145
170
170
275
275
275
275
62
74
68
82
91
82
90
88
100
120
107
124
150
138
168
150
175
200
210
80
80
91
91
91
112
112
119
119
119
145
145
145
157
157
255
255
275
275
62
74
68
82
91
82
90
88
100
120
107
124
150
138
168
150
175
190
200
80
80
91
91
91
112
112
119
119
119
145
145
145
157
157
255
255
255
255
50
50
64
64
64
80
80
90
90
90
122
122
122
135
135
190
190
190
190
44
56
47
61
70
61
70
68
80
100
82
99
125
110
141
200
200
200
200
4.8 x 8
4.8 x 8
4.8 x 8
4.8 x 8
4.8 x 8
5.8 x 9
5.8 x 9
5.8 x 12
5.8 x 12
5.8 x 12
7 x 15
7 x 15
7 x 15
7 x 15
7 x 15
11
11
11
11
55
67
60
74
83
80
89
86
98
118
104
121
147
136
167
130
155
170
180
60
60
76
76
76
97
97
106
106
106
132
132
132
152
152
250
250
250
250
kg W W % 12 V 24 V 42 V 110 V 230 V
Total
weight
1) Connection lugs
2) For type ET/ETSP 0,03 - 0,2 earth connection downwards
Fig.1
Fig.2
Fig.3
*) depending on the
voltage ratio
all dimensions in mm
1) Material surcharge –› page 64
higher voltage