Single-phase transformers, three-phase transformers0 pages
Gross prices! · phone +43 / 26 89 / 27 44 - 0 · fax +43 / 26 89 / 27 44 - 9 · info@trafomodern.com · www.trafomodern.com Gross prices! · phone +43 / 26 89 / 27 44 - 44 0 · fax +43 / 26 89 / 27 44 - 9 · info@trafomodern.com · www.trafomodern.com
Transformers for use in medical environments
Single-phase transformers, three-phase transformers
ET-MED
DT-MED
Designed and tested according to
· IEC/EN 61558-2-15
· VDE 0570-2-15
For use according to
· EN 7
· VDE 0100 part 710
Typical applications
· Isolating transformers for use
in medical environments
Basic equipment
· Separate windings
· Insulation class B
· Ambient temperature –25 to 40 °C
· Connection terminal (<63 A)
· Frequency 50/60 Hz
· Static shield winding
· Temperature Control by PTC-resistor
Further equipment
· Enclosure IP23 on request
· Other temperature controls
45
Transformers for use in medical environments
Single-phase transformers ET-MED, three-phase transformers DT-MED
Type No-load a b b1
losses
Shortcircuit
losses
Shortcircuit
voltage
Efficiency
factor
c c1 e f
DT3,15-MED
DT4,0-MED
DT5,0-MED
DT6,3-MED
DT8,0-MED
36
40
55
60
70
26
34
50
66
75
85
117
138
202
213
–––––
0.96
0.96
0.96
0.96
0.96
300
300
300
390
390
210
240
255
225
240
135
147
162
153
168
335
335
335
374
374
260
260
260
305
305
224
224
224
350
350
107
119
134
127
142
kg W W %
Total
weight
Type No-load a b b1
losses
Shortcircuit
losses
Shortcircuit
voltage
Efficiency
factor
c c1 e f ø g
ET3,15-MED
ET4,0-MED
ET5,3-MED
ET6,3-MED
ET8,3-MED
31
35
45
55
60
23
22
24
24
31
97
100
164
181
215
–––––
0.96
0.96
0.96
0.96
0.97
200
260
260
260
320
205
179
194
209
224
162
153
168
183
205
340
422
375
422
440
260
305
310
305
365
124
230
230
230
270
134
127
143
157
177
10 x 18
10 x 18
10 x 18
10 x 18
13 x 20
kg W W %
Total
weight
kVA V V Euro
3.15 230 230 ET3,15(230/230)-MED 663.20 9.00
991033
4 ET4,0(230/230)-MED 926.60 17.00
991034
5.3 ET5,3(230/230)-MED 1,034.30 18.00
991035
6.3 ET6,3(230/230)-MED 1,146.10 19.00
991036
8.3 ET8,3(230/230)-MED 1,279.70 22.70
991037
3.15 400 230 DT3,15(400/230)-MED 893.90 8.00
991038
4 DT4,0(400/230)-MED 985.90 13.00
991039
5 DT5,0(400/230)-MED 1,105.20 15.00
991040
6.3 DT6,3(400/230)-MED 1,253.60 23.00
991041
8 DT8,0(400/230)-MED 1,481.50 24.00
991042
Rated outputs Rated input
voltage
Rated output
voltage
Type
Order no.
Cu-factor1)
Other voltage combinations can be designed
on request.
In most applications the standard configuration
is needed which is described in the
table. If other voltage combinations are
needed, the input voltage and the output voltage
must be added to the order like follows:
DT3,15(*/*)-MED
1st place holder ^=
rated input voltage
2nd place holder ^=
rated output voltage
Sample order
• requested type DT4,0...-MED
• requested rated input voltage 400 V
• requested rated output voltage 230 V
The correct type designation reads
DT4,0(400/230)-MED
1) Material surcharge –› page 64
all dimensions in mm
all dimensions in mm
Price
per unit