SC750 Series0 pages
SC750 Series
Wiring Diagram
L1 - Power ON (Green)
L2 - Output Status (Red
L3 - Sensor Status (Delay) Yellow
P1 - Sensitivity Adjustment
P2 - Time Delay Adjustment
SC700DC/ SC750DC With N1 Housing
Relay Contact
5A-250Vac
Power Supply
24Vac
1 - Positive DC
2 - Negative DC
3 - Ground
4 - NO Contact
5 - Common
6 - NC Contact
L2
3
2
1
L1
ON
24Vdc
4
P2
6
5
NO C NC
SC700
L3
P1
SC700U/ SC750U With G2 Housing
Power Supply
Time Delay Adjustment
8
1 - Power Supply
2 - Power Supply
3 - Ground
4 - Common
5 - NO Contact
6 - Common
7 - NC Contact
SC 700
9
L1
L3
4 5 6
3
+
24 Vdc
L2
10
7
8
9
10
2
1
0
1
20 sec.
Sensitivity
Delay
P1
1
8 - Positive DC
9 - Negative DC
2
3
H
P2
4
5
6
7
Sensitivity Adjustment
L
NO
NC
Relay Contact
High/Low
Sitron - Brasil
R. Baronesa de Itu, 83
São Paulo - SP - 01231-001
T.: (5511) 3825-2111
F.: (5511) 3825-2171
Sitron - USA
1800 Prime Place
Hauppauge, NY 11788
PH: 516-935-8001
FX: 800-516-1656
www.sitron.com
BRASIL: vendas@sitron.com
USA / Other Countries: info@sitron.com