5080 PAT Calibrator Data Sheet0 pages
Time Electronics
5080 PATCAL – Portable Appliance Tester Calibrator
• For calibration of PATs and VDE 0701 testers
• Earth bond range 18Ω to 20mΩ
• Earth bond currents up to 50A AC
• Load test currents up to 13A AC
• V & I displayed on integral LCD digital meter
• Safety interlock feature
• Battery operation (>200 hrs between charges)
• Portable and robust carrying case
DESCRIPTION
A precision calibrator designed to provide rapid high accuracy calibration of portable appliance testers and insulation/
continuity testers. The 5080 has calibration functions for earth bond, insulation, leakage, touch leakage, and load test.
Housed in a robust safety case the 5080 is easily portable and ideal for field calibration work. It is battery powered,
which ensures isolation and prevents inaccuracies due to stray leakage. Features include safety interlock that prevents
contact with earth bond studs during insulation and leakage tests, and an LCD display for voltage and current.
SPECIFICATIONS
Earth Bond – Calibrated low value resistive loads
20mΩ, accuracy 5%. 190mΩ, 210mΩ, 950mΩ, 1.050mΩ, 1.08Ω, 2Ω, 10Ω, 18Ω, accuracy 1%
Open circuit voltage measurement.......... Range: 0 to 20V. Accuracy: 0.25% of full scale
High current AC measurement................. Range: 0 to 50A AC. Accuracy: 0.5% of reading +/- 0.2A
Low current AC measurement.................. Range: 0 to 2A AC. Accuracy: 0.5% of reading +/- 2mA
Low current DC measurement.................. Range: 0 to 2A DC. Accuracy: 1% of reading +/- 2mA
Insulation – Calibrated high value resistive loads
95kΩ, 105kΩ, 500kΩ, 950kΩ, 1.05MΩ, 5MΩ, 10MΩ, accuracy 0.1%. 20MΩ, 50MΩ, 100MΩ, accuracy 1.0%
Open circuit voltage measurement.......... Range: 0 to 1kV DC. Accuracy: 0.25% of full scale
Current measurement............................... Range: 0 to 20mA DC. Accuracy: 0.25% of full scale
Leakage – Resistive loads for leakage current
Nominal leakage currents at 230V AC of 0.5, 1, 2, 5, 10, 15mA
Mains voltage measurement.................... Range: 0 to 500V AC. Accuracy 0.25% of full scale
Leakage current measurement................. Range: 0 to 20mA AC. Accuracy 0.25% of full scale
Touch Leakage – Constant current source for touch leakage meters
Current...................................................... 1.9mA AC 50 +/-5 Hz, into 2K2 maximum load resistance
Current measurement............................... Range: 0 to 2mA AC. Accuracy: 0.25% of full scale
Load Test – Connection of external load via a IEC connector
Mains voltage measurement.................... Range: 0 to 500V AC. Accuracy: 0.25% of full scale
Load current measurement...................... Range: 0 to 13A AC. Accuracy: 0.5% of full scale
Dimensions / Weight................................. W406 x H175 x D330mm, weight 5.5kg
Power........................................................ Internal battery 6V re-chargeable NiCad, >200 hrs between charges.
ORDERING INFORMATION
5080.......................................................... PATCAL – Portable Appliance Tester Calibrator
C188.......................................................... Factory Calibration Certificate (NPL)
C135.......................................................... UKAS Calibration Certificate (17025)
Due to continuous development Time Electronics reserves
the right to change specifications without prior notice.
Time Electronics Ltd, Unit 11 Sovereign Way, Botany Industrial Estate, Tonbridge, Kent, TN9 1RH. United Kingdom.
T: +44 (0) 1732 355993 F: +44 (0) 1732 770312 E: mail@timeelectronics.co.uk
www.timeelectronics.com
v2a 22/3/11
"