TEDDINGTON APPLIANCE CONTROLS LTD
COMSA 006
COMBINATION VALVES
? Approved
CE, CSA
? (40”) WG Max. Pressure
150mbar
?
1/2psi Maximum Inlet Pressure
?
Temperature Differential ±10°C (±18°F)
? 120°C Ambient Temperature (10°F - 250°F)
-14°C ? Mounting Positions
Universal
? Available for Electronic Ignition
Switch
? for Natural, Towns and LPG Gases
Suitable
? Knob Available
Standard
COMSA006R
Application
The Teddington Appliance Controls Combustion Valve
combines a tap, flame safety device and precision
thermostatic gas control. With CSA and CE approval, the
control is deigned to function on a wide range of catering Operation
appliances.
This consists of pushing the spindle in to clear the niting
Physical Description
followed by rotation to the ignition position. The spindle
is then pushed in to allow gas to the pilot. The
The COMSA body is constructed of aluminium or
aluminium and brass, depending on type, and is
connected to the sensor by a copper capillary.
COMSA's are available with inlet, outlet and pilot
temperature settings are obtained by further rotation of
the spindle.
Operating times
arrangement to suit virtually all-standard appliances,
Opening 20sec. maximum (depending upon application)
connections are illustrated overleaf.
Closing 60sec. maximum (depending upon application)
Capillary lengths: 762, 1219 and 1651mm
Maximum Phial Temperature
315°C (600°F) cooking version
60°C (140°F) space heating version