Walk-In Temperature & Humidity Test Room
a m »A .
Application:
Walk-In Temperature & Humidity Test Room is used to test various types of materials for their tolerances of heat,
cold, dry, humidity. It is applied for quality inspection for all types of big test samples, such as electronic products,
electric appliance, and products from commu nication, instrument, automobile, plastic, metal, food, chemical,
building materials, medical and aerospace industries.
•w&wmmmm&m&m "mm- is, mzm%i£?&mmm^mmBmm&m±mmMmmmmR23,R404A).
•ffifyatM^^isfiieiiiiRiSjtMJt. psw&m ( OUICK ) ssmm ( SLOP ) e$y
Features:
• Graceful appearance, circularly shaped body, surface treated with mist strips and plane handle with no reaction. Easy
to operate, safe and reliable.
• Rectangular double-glassed watching window for the observation of the test production du ring the testing process.
The window is equipped with sweat-proof electrical heating device that can prevent water steam from condensing
into droplets, and with high brightness PL fluorescent bu lbs to provide light inside the box.
• Double-layer-insulated airtight doors, able to insulate the internal temperature effectively.
•Water supply system that is externally connectable, convenient for refilling water into the hu midifying pot and
automatically recyclable.
•The French "Tecumseh" brand is used for the circu lation system of the compressor, capable of removing the
lubricant between the condensation pipes and capillaries. The environment-protecting coolant is used for the whole
series(R23 , R404A)
•Imported LCD display screen, capable of displaying the measu red value as well as the set value and time.
•The control unit has the functions of multiples segment program editing, and of quick or slope control of
temperature and humidity.
•Inserted mobile pulley, convenient for movement a relocation, with strong positioning screws.
-^09 <£L
iSiaS^ Professional Testing Equipment Manufacturer
^MJt^yib^iBH Humidity Control Range ^IJSIl^ffl^B
At + 20°CAmbienttemperatureor+25°C Room temperatured and non-loaded Ternperatu re and Humidity Cycle Graph
&j$jfll&Technical Parameters:
Model | THR-#«(ffifflSg : A~ F) THR-volume (low-temperature options : A ~ F) |
Internal Dimension | Customers designated space size and design |
Temperature Range | fE)S ( A:25°C ; B : 0°C ; C : -20°C ; D : -40°C ; E : -60°C ; F : -70°C ) MS8o°c (8o°c ~i5o°c^mmmm) LowTemperature ( A:25°C ; B:0°C ; C:-20°C ; D:-40°C ; E:-60°C ; F:-70°C ) High Temperature 80°C ( 80°C ~150°C is special optional ) |
m&mm Humidity Range | 20%~98%R.H.(10%~98% R.H./ 5%~98% R.H^iSIfflHffflra&li| 20%~98%R.H.(10%~98% R.H./ 5%~98% R.H,is a special optional condition, need dehumidifier) |
Analytic Accuracy/ Distribution Uniformity of Temperature and Humidity | 0.1°C ; 0.1% R.H ±3.5°C ; ±4.5% R.H. |
Control Accuracy of Temperature and Humidity | ±0.5°C ±2.5% R.H. |
Temperature Rising / Falling Speed Rate | ^si$mi~3.o°c/£-a ; p$;sii^ao.i~i.o°c/»ii (mi&&m..o°c/&M\:xt j&tfeffiMMtikft ) Temperature rising approx. 0.1 ~3.0°C/min , temperature falling approx. 0.1~1.0°C/min; (The Falling Speed Rate Min.l.0°C per minute is a special optional condition) |
/#§PM#5/Cooling System | 7tO#iC Watercooling |
Protection Devices | m>mmm. mmmmmimrm. mm&m&mrm. mimm^mmm. « tMnlii, WKMzWUM Fuse-free switch, overloading protection switch for com pressor, high and low voltage coolant protection switch, over-hu midity and over-temperature protection switch, fuses, fau It warning system, watershort storage warning protection |
Optional Accessories | Slope forcart, Recorder, Water Purifier, Dehumidifier |
JIM/Com pressor | ;£H "MB." IS, fill "tbiOH" French "Tecumseh" Brand, Germany "Bizer" Brand |
W)WJ Power | AC380V ; 3$ 511 ; 50/60HZ AC380V ; 3# 5 lines ; 50/60HZ |