5200MP0 pages
SERVOFLEX MiniMP (5200 Multipurpose)
nnnnPORTABLE BENCHTOP GAS ANALYSER
nnnnFor analysing the composition of common gas mixtures in
nnnnlaboratories and light industrial applications
nnnnNon-depleting paramagnetic and infrared
nnnnmeasurement technology ensures the unit is
nnnnalways ready for use
nnnnAccurate, reliable and component specific,
nnnngiving confidence that observed values
nnnnare credible and not due to background
nnnninterference
nnnnCustomer pre-tested software offers ease of use,
nnnnsimple calibration and advanced features
nnnnInnovative construction gives a robust unit with a
nnnnspace saving footprint
nnnnRechargeable battery and vehicle power (12/24V)
nnnnoptions enable mobile use
nnnnSPECIFICATION
nnnnGASES MEASURED
nnnnOxygen (0?) and/or Carbon Dioxide (CO?)
nnnnSENSORS
nnnnTechnology:
nnnnVariant:
nnnnFull scale range (FSR):
nnnnMinimum output range:
nnnnCell construction:
nnnnDecimal places:
nnnnPERFORMANCE
nnnnAccuracy, general use:
nnnnAccuracy, stable environment:
nnnnZero drift, per week:
nnnnResponse time (Tgo):
nnnnTilt effect, at 15° from caI:
nnnnPressure effect:
nnnnFlow variation effect:
nnnnOperating temperature:
nnnnTemp, coefficient, zero:
nnnnTemp, coefficient, span:
nnnnTemp, coefficient, span:
nnnnSAMPLE
nnnnSample gas:
nnnnFlow control:
nnnnSample inlet connection:
nnnnSample outlet connection:
nnnnInlet pressure:
nnnnSample filter:
nnnnStandard
nnnn0-100% 02
nnnn0-10% 02
nnnnPolymer (PPS)
nnnn1
nnnn±0.2% 02
nnnn±0.1% 02
nnnnOXYGEN
nnnnParamagnetic
nnnnIndustrial
nnnn0-100% 02
nnnn0-1 % 02
nnnn316 Stainless Steel
nnnn1
nnnn±0.1% 02
nnnn±0.1% 02
nnnn±0.2% O,
nnnnHigh accuracy
nnnn0-100% 02
nnnn0-1 % 02
nnnn316 Stainless Steel
nnnn2
nnnn±0.05% 02
nnnn±0.02% 02
nnnn±0.2% O,
nnnn±0.4% 02
nnnn<10 seconds <15 seconds <15 seconds
nnnn±0.3% 02 ±0.15% 02 ±0.15% 02
nnnnDirectly proportional to ambient barometric pressure
nnnn±0.1 % 02 for a ±0.5psig (3.5kPa) change
nnnn-10°C to +50°C (+14°F to +122°F)
nnnn±0.2% 02 per 10°C (18°F)
nnnn±0.3% 02 per 10°C (18°F)
nnnn±0.3% 02 per 10°C (18°F)
nnnnCARBON DIOXIDE
nnnnInfrared
nnnnAll variants
nnnn10%, 25%, 50%, 100%
nnnn0-10% FSR
nnnn316 Stainless Steel
nnnnRanges <10%:2 >10%:1
nnnn±2% FSR
nnnn±1 % FSR (after 20 mins warm up)
nnnn±4% FSR
nnnn<10 seconds
nnnn±1 % FSR
nnnn<0.2% reading/ mBar change
nnnn±0.5% FSR for a 10psig (70kPa) change
nnnn5°C to +45°C (+41 °F to +113°F)
nnnn±1% FSR/10°C (18°F)
nnnn±5% FSR/ 10°C (18°F)(exc. 100% C02)
nnnn±8.5% FSR/ 10°C (18°F) 100% C02 only
nnnnClean, dry, non-flammable and non-toxic gases only.
nnnnNote: Though samples containing >5% C02 are toxic they can be analysed if suitable precautions are taken.
nnnnTo maximise measurement stability, unpumped units are supplied with an automatic flow control device (AFCD)
nnnnOver the specified inlet pressure range this controls sample flow rate to approximately 1.5 to 6 litres
nnnn(0.05 to 0.2 cubic feet) per minute
nnnn5mm OD stub with "Quickconnect" barb fitting for 6.3mm OA") ID tube or adaptor to Vs" NPT fitting option
nnnn5mm OD stub (sample and bypass)
nnnnWithout pump 7kPa (1 psig) to 70kPa (1 Opsig)
nnnnWith optional internal pump -7kPa (-1 psig) to 3.5kPa (0.5psig)
nnnnReplaceable 0.6um glass fibre particulate filter
nnnnResponse time - All at Wpsig (70kPa)
nnnnFlow effect - AFCD version, within specified sample gas supply range
nnnnSERVOMEX\
"