Temperature Humidity Salt Spray Combined Test Chamber
maai
Application:
Temperature humidity salt combined test Chamber is used for imitating natural status in increase imitation test.
The imitating condition is harder than status that we usually meet. The tester can combine the follow status such
as: salt smog, dry, humidity, normal temperature, low temperature.The tester is for product used in intense changeable
environment, such as: parts of automobile, navigation equipment, camera equipment, building material, electroplate
coating and resistant to metal electrolytic corrosion in electrical system.
tttt:
ammmms)
•fSieaiT^iooii, mmioom., mmioom^m.
• ^fiafTl0000^@/J\B#
Features:
•Adopt Humidity and temperature Controller with LCD touch screen digital display, RS232 or RS485 communication interface.
(Temperature and humidity recorder, can keep complete records of the humidity and temperature graphs. This is optional.)
• Operation mode: programmable or constant
• Capacity of Programmable operation islOOgroupslOOstepsperg roup, and 100 H per step
• Capacity of constant operation is 10000H.
• Memory function: in case of a power cut, the machine can resume the unfinished test as soon as power is recovered.
— 15 S=r,as»«,3gcz
twSllfSl§,i3-iwlSl'#fi'5SiaS^ Professional Testing Equipment Manufacturer
JSffijUIfc Technical Parameters:
Ml Model | THS-900A | THS-900B |
III WSM Te st St a n d a rd | ACSS , SOAK , DRYAIR , HUMI, ROOMAIR | ACSS, DRYAIR, HUMI |
rt^R\TWxHxD(mm) Internal Dimension WxHxD ( mm ) | 900x600x500 | 900x600x500 |
WxHxD(mm) External Dimension WxHxD ( mm ) | 1500x1300x1000 | 1500x1300x1000 |
imJSifiH/ Temperature Range | -10°C ~ +80°C | RT(+15°C) ~ +80°C |
1JSI6H Humidity Range | 60% ~ 95%R.H.(;£JS£RT(+15°C) ~80°C) 60% ~ 95%R.H.(Temperature RT(+15°C) ~ 80°C) | 60% ~ 95%R.H.(60°C ~ 70°C) |
Analytic Accuracy/Distribution Uniformity of Temperature and Humidity | 0.1°C ; 0.1% R.H ±2.0°C ; ±3.0% R.H. | |
SlJSfilUllJS Control Accuracy of Temperature and Humidity | ±0.5°C ±2.5% R.H. | |
MZJfflumJS Pressure Bucket Temperature | S7KIJSOD;i(NSS ACSS)47±1°C; j|It«75;i(CASS)63±l °C Saline test method (NSS ACSS) 47±1 °C ; Corrosion Test (CASS)63±1 °C | |
Bt£*lI*(KGf) Compressed Air Pressure (KGf) | 1.0-6.0 | |
01 Urn Spray Volume | 1.0-2.0ml /80cm2/h (££j>Hfcill6/J\B$ , K«¥±«lfi) 1.0-2.0ml /80cm2/h(working at least 16 hours, and take the average value) | |
DiR&it/Spray Method | JjUlitDJtH Continuous spray | |
MiWJ Power | AC380V ; 3$5^$ ; 10A AC380V ; 3§S lines; 10A | AC220V; l$3^i; 15A AC220V ; 1$ 3 lines; 15A |