94 series0 pages
Series 94
Electric Actuator
Standard Features
• Motor: Reversing, brushless, capacitor-run 115 VAC
50/60 Hz, single phase
• Overload protection: Integral thermal overload
protection for motor windings with automatic reset
• Gear train: Permanently lubricated
• Corrosion resistant housing: Zytel FR50 engineered
resin rated Type 4X with stainless steel trim
• ISO mounting configuration
• Conduit: Two 1/2" NPT conduit entries to eliminate
cross feed between control, feedback, and power
signals
• Position indication: Highly visible position indicator for
positive position of valve
• Declutchable manual override: Push down on handle and
rotate in the appropriate direction (CCW for open,
CW for close)
UL-508
Listed
Options
• Auxiliary (additional) limit switches
• Feedback potentiometer
• Heater and thermostat
• Limit switches: Standard end of travel limit switches
can be used for light indication
(not to be use with PLC for position confirmation)
• Positioner (modulating PCB)
• Corrosion resistant mounting: Mounting is with PPG or
stainless steel bracket, stainless steel coupling, and
stainless steel hardware
• Mechanical brake
• Transmitter
• Cycle length control module (CLC)
• CE compliant motor: All 115 VAC and 230 VAC motors
are CE compliant and stamped as such
• Two-wire control
• Extended duty cycles: Our extended duty cycles
are ideal for modulating and high cycling applications
• Failsafe battery back up (Protek)
• Output torque: Series 94 electric actuators have an
output torque range from 150 in/lbs. to 300 in./lbs.
• Enclosure: Corrosion proof weatherproof rated Type 4X
• Captivated SS hex head slotted cover screws
A94
B94
115 VAC
• Local Remote Station
See page 194 for more details regarding options.
Engineering Specifications
Engineering Data
Torque
(in/lbs)
• Voltages
Size: A94, B94
Torque: 150-300 in/lbs
Voltage: 120 VAC 1Ph 50/60 Hz
Amp Draw: A94 .5A, B94 .8A
Conduit Entry: Two (2) 1/2" NPT
Max Ambient Temperature: 150º F
Switches: Two single pole, double throw (Two SPDT)
15 amp rated
Cycle Time per 90º: A94, B94: 5 seconds
• RoHS compliant
Model
• Center-off
230 VAC
12 VDC
24 VDC
12 VDC
Amp
Draw
Duty
Cycle
Amp
Draw
Duty
Cycle
Amp
Draw
Duty
Cycle
150
0.5
100%
0.4
100%
2.0
75%
4.0
75%
2.0
300
0.8
75%
0.6
75%
2.0
75%
4.0
75%
2.0
24 VAC
Amp
Draw
Duty
Cycle
Cycle Time per
90 Degrees
(seconds)*
Weight
(lbs)
75%
4.0
75%
5
3.5
75%
4.0
75%
5
3.5
Amp Duty Amp Duty
Draw Cycle Draw Cycle
Note: Amp rating is considered locked rotor. Duty cycles are for ambient temperature (73º F).