PVXC "VORTEX" Fixed installation pumps for sewage water0 pages
PVXC
"VORTEX"
Fixed installation pumps
➠ for sewage water
PERFORMANCE RANGE
INSTALLATION AND USE
•
•
PVXC series pumps, made from heavy gauge cast iron offering
exceptional sturdiness, abrasion resistance and durability, come
equipped with a VORTEX impeller and are therefore suitable for
draining waste water, water mixed with mud, liquids containing air or gas, as well as sludge. They are suitable for use in fixed
sewer, tunnel, well and underground car park installations.
Flow rate up to 1200 l/min (72 m3/h)
Head up to 16 m
APPLICATION LIMITS
•
•
•
•
10 m maximum immersion depth
Maximum liquid temperature +40 °C
Solids passage:
– up to Ø 50 mm for PVXC 15-20-30/50
– up to Ø 70 mm for PVXC 15-20-30/70
Minimum immersion depth for continuous service:
– 390 mm for PVXC 15-20-30/50
– 440 mm for PVXC 15-20-30/70
CONSTRUCTION AND SAFETY STANDARDS
•
•
•
Standard features: base pedestal, threaded delivery counterflange, guide tube supports
10 m long power cable
Float switch for single-phase versions
EN 60034-1
IEC 60034-1
CEI 2-3
CERTIFICATIONS
318
PATENTS - TRADE MARKS - MODELS
•
Registered Community Design n° 342159-0017
OPTIONALS AVAILABLE ON REQUEST
•
•
•
•
QES control box for three-phase pumps
Three-phase dual voltage pumps:
– 230/400 V or
– 400/690 V
Single-phase pumps without float switch
Other voltages or 60 Hz frequency
GUARANTEE
2 years subject to terms and conditions
➠ For the following versions the built-in thermal overload
protector must be connected to the control box in order for
the guarantee to be considered valid:
single-phase
three-phase
– PVXCm 30/50 - HP 3
– PVXC 15-20-30/50 - HP 1.5-2-3
– PVXCm 30/70 - HP 3
– PVXC 15-20-30/70 - HP 1.5-2-3