Complete Overview 20100 pages
Return Loss Meter
Fiber Type: Singlemode Multimode
Source Wavelength 1310nm/1550nm (1490nm/1625nm) 850nm or 1300nm
Measurement Range -10dB..-72dB (-80dB FTTX) -10dB..-55dB
Absolute Accuracy +/-1dB, -14..65 +/- 2dB 65..72 +/-1dB -10..-45, +/- 2dB 45..55
Distance Range (Reference Cable to DUT) 2.5m..2400m
Multichannel Source
Source Type: LED Laser
Wavelength (individual) POF, 850nm, 1300nm 850nm, 1310nm, 1550nm, 1625nm
Dual Wavelength 850nm/1300nm 1310nm/1550nm
Output Power -13dBm (output power depends on fiber size) 0dBm
Stability (1 hour @ Ambient, Overall) +/- 0.02dB, +/- 0.05dB +/- 0.02dB, +/- 0.05dB
Number of Channels Up to 24 individual or dual wavelength sources per instrument
Optical Interface FC, ST, SC (others upon request)
Multichannel Optical Power Meter
Detector (various detector areas available) InGaAs (1mm, 3mm, 5mm,10mm) Silicon (3mm)
Measurement Range +3dBm..-80dBm, +27dBm .. -55dBm +3dBm..-60dBm
Wavelength Range 830nm..1700nm 480nm..1080nm
Selectable Wavelength 850/980/1310/1480/1550/1625nm 650/850/980nm
Measurement Resolution (Display) 0.01dBm (absolute) 0.001dB (relative)
Measurement Linearity (Relative Accuracy) +/-0.05dB
Number of Channels 4 to 24 per instrument
Data Acquisition Rate >10 samples/second acquisition rate
OP710
Insertion Loss Measurement
The OP815 offers a highly integrated, single unit solution for
efficiently measuring insertion loss on singlemode, mulitmode
fiber cable as well as POF. The instrument includes a single
dual-precision optical power meter and a single or dual
wavelength light source.
Optical Power Meter
Measurement Range +3dBm..-80dBm
Wavelength Range 830nm..1700nm (InGaAs Detector) 480nm ... 1080nm (Silicon Detector)
Selectable Wavelength Standard: 850/980/1300/1310/1480/1550/1625nm 630/650/780/850/980nm
Measurement Resolution (Display) 0.01dBm (absolute) 0.001dB (relative)
Measurement Linearity (Relative Accuracy)*** 0.05dB
Stabilized Source: Laser LED
Source Wavelength 850nm, 1310nm, 1550nm, 1490nm, 1625nm * 850nm, 1300nm or both, 650nm *
Output Power typ. 0 dBm (1mW) typ. -15dBm (into 62.5MM)
Launch* * Singlemode CPR>21dB
Source & Power Channels 1 or 2 each
OP815 & OP815D
Bidirectional Insertion Loss Measurement
Built upon the proven technology of the OP815
and equipped with a highly repeatable cross
connect switch, the OP831 is the efficient
solution to measure insertion loss on both
ends of singlemode or multimode cables in one
measurement.
Optical Power Meter
Measurement Repeatability IL +/- 0.075dB (includes 2x2 switch, source stability, power meter linearity)
Measurement Time (Dual wavelength both directions) 3 sec. (For best repeatability)
Multichannel Instruments
Multichannel Optical Power Meter
The OP710 offers unparalleled data acquisition
speed for multichannel optical power measurements.
Configurable with a variety of detectors and
connector interfaces multiple instruments can be
combined for a higher channel count.
Multichannel Source
The OP750 multichannel source can be
configured for a mix of up to 24 individual
LED or Laser sources. Depending on the
application, individual sources or a switched
solution can be configured.
Multifiber/Ribbon Testing
OP831
OP710 Multichannel Optical Power Meter Low Polarization Dependence (LPD) , High Power, and Wide Spectral Response (WSR) models are available.
OP750
Instrument Selection
Besides the Turnkey Solution for 12 fiber MTP/
MPO connectorized cables and hybrids, OptoTest
offers a variety of instruments and options that
are engineered to match the measurement
applications, be it simplex, duplex, ribbon, or
multi-fiber cables terminated with any of the
industry available connectors.
Return Loss Measurement
The Insertion Loss and Return Loss on optical
components is measured fast and accurately with
the TIA approved “no mandrel” method. Neither
matching gel nor mandrel wraps are required for
testing of the cable.
OP930
OPL Application Software
Insertion Loss & Return Loss Measurement
Reflective Event Comparison Method (RECM) per TIA TSB-142.
Fiber Type: Multimode Singlemode
Source Channels 4...12, 24 (or custom)
Insertion Loss Source 850nm, 1300nm
Launch Condition TIA compliant
1310nm, 1550nm
1490nm, 1625nm
Return Loss Source 850nm, 1310nm 1310nm, 1550nm
1490nm, 1625nm
Source Stability +/-0.02dB (0.05dB)
Optical Power Meter Range
(for 5mm, 10mm Detector or
Integrating Sphere)
+3dBm ... -45dBm
Insertion Loss Accuracy +/- 0.05dB
Return Loss Range -10dB .. -52dB -10dB .. -72dB
Return Loss Accuracy * +/-1dB
Channel Repeatability +/-0.05dB
Measurement Speed typ.1 sec.per channel & wavelength pair
OPL-Pro
This cable test utility automates the Insertion Loss,
Return Loss measurement process in manufacturing
greatly. OPL-Pro operates with all single channel and
bidirectional instruments.
• Real-time display
• Pass/Fail criteria
• Serialized Cable Test
• Bidirectional Testing
• Datafile in Excel format
• User configurable setup
• Auditing trails
OPL-Max
This application supports multichannel
serialized cable testing for
Insertion Loss and Return Loss..
• Programmable Sequences
• Reference Wizard
• Checks for Continuity/
Crossed Fiber
• Retest of individual channels
• Test Report
• Data in Excel format
• Measurement Log for audits
OPL-LOG
A customizable application controlling
combinations of Sources, Return Loss
modules, power meters, and third party
instruments, to log data over time.
• Timer based data acquisition
• Capture IL, RL, temperature and auxiliary
parameters
• Data in Excel format
• Programmable Sequences
• Graphical display of results vs. time
Singlemode fiber 5mm Detector
Integrating Sphere
SM/MM fiber 10mm Detector
Integrating Sphere
Bare ribbon fiber (any type)
10mm Detector
Integrating Sphere
Measuring Insertion Loss (IL) and
Return Loss (RL) on multiple fibers can be
challenging; the connectors may be difficult
to clean, high quality reference cables may
be hard to get and the measurement step
requires fiber management and organizational
skills beyond belief.
With the OPSeries Multifiber Test Systems,
tailored solutions measure the necessary
parameters on Multifiber cables such as
MTP/MPO Cables, Fanouts, Multi-termini
Connectors, and even Duplex or Simplex
Cables.
OP930
OP815
OP831
OP750
OP710
Optical Power Meter : Same per formance as the OP815 & OP815D.
Stabilized Source: Same per formance as the OP815 & OP815D.
Appropriate Detector Selection
To measure power levels on ribbon fibers terminated
with any of the MT connectors styles, the following
* Others upon request ** Can be configured per customer's request including encircles flux per TIA/IEC *** Dynamic Range depends on detector type. large area detector options are supported:
* mm: -10..-45, 5m -10...-65, +/-2dB otherwise