E3S-CL0 pages
Distance-settable Photoelectric Sensor with Metal Case
E3S-CL
CSM_E3S-CL_DS_E_4_2
Simply Set the Distance to Reliably
Detect Workpieces of Various Colors
• Reliable detection regardless of color or material.
Black/white error of only 2% max. (E3S-CL1)
• Long sensing distance of 500 mm (E3S-CL2).
• Eliminates background influence.
(Differential travel of only 2% max. with E3S-CL1.)
• Metal body with IP67 protection.
Oil resistance (E3S-CL2).
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read Safety Precautions on
page 7.
Ordering Information
Sensors
(Refer to Dimensions on page 8.)
Red light
Appearance
Sensing/Setting range
5
Infrared light
Model
40 mm
Min. setting
5
Setting range
40 to 200 mm
Max. setting
Sensing range
E3S-CL1 2M
200 mm
5 to 200 mm
5
Min. setting
50 mm
Setting range
Max. setting
5
50 to 500 mm
Sensing range
E3S-CL2 2M
500 mm
5 to 500 mm