AirAware?0 pages
ENVIRONMENTAL AIR MONITORING
t Institutional, commercial and light industrial monitoring
t Monitor any one of nine gases
VDC operation, or
t Simple installation using 12-24that plugs into any
an optional AC power adapter
standard 120 VAC wall outlet (North American plug).
t Bright display constantly shows gas concentrations
t Single button calibration, alarm muting and zero
functions
t Visual alarm to alert of potential gas hazards t
(audio optional)
t ModBus digital output (4-20 mA output optional) for
interfacing with control devices
dual-alarm relays can
t Optional sirens, or shut-down a turn on fans and
warning
process.
Specifications
Case
t NEMA 4 type, General purpose indoor use.
t Electroplated for RFI protection.
Dimensions
t 18.29 cm x 14.22 cm x 4.06 cm (7.2″ x 5.6″ x 1.6″ )
Weight
t 454 g (16 oz)
Industry proven performance combined with a low-profile
design make a logical choice for those areas that require
continuous monitoring but not the environmental protection of
an explosion-proof enclosure. Providing discrete monitoring
and enhanced aesthetics for more commercial or institutional
settings, the AirAware Series is the ideal solution for reliable,
low-cost fixed-point monitoring.
The AirAware can be configured to operate as a monitor with
local LED display, a controller with onboard relay switching
capability, a transmitter with 4-20 mA or ModBus RTU outputs,
or as a transmitter with on-board relays. Each configuration is
designed to meet your specific indoor monitoring needs.
Every AirAware is equipped with electrochemical sensing technology, dual alarm LEDs, push-button operation and a NEMA 4
type enclosure.
Configure your AirAware to match your needs, adding options
such as a vanity plate to hide the display. The AirAware is
covered by a one-year warranty and carries CSA approval for
non-hazardous locations.
The Fixed Gas Detection People
www.oldhamgas.com
Sensor Type
tElectrochemicalt
Measuring Ranges
t Carbon Monoxide, Hydrogen Sulfide – 0 to 999 ppm in 1 ppm increments
t Nitric Oxide – 0 to 999 ppm in 1 ppm increments
t Ammonia – 0 to 200 ppm in 1 ppm increments
t Oxygen – 0 to 30% by volume in 0.1% increments
t Sulfur Dioxide, Nitrogen Dioxide – 0.2 to 99.9 ppm int 0.1 ppm increments
t Chlorine – 0.2 to 50 ppm in 0.1 ppm increments
t Hydrogen Chloride – 0.2 to 30 ppm in 0.1 ppm increments
Power Source (Run Time)
t 12-24 VDC (110 AC adapter optional with North American plug)
Temperature Ranges:
t -20°C to 50°C (-4°F to 122°F ) typical, consult factory for gas
t specific temperature ranges
Humidity Range
t Oxygen – 0-99%
t Ammonia, Carbon Monoxide, Hydrogen Sulfide, Nitrogen Dioxide,
t t Sulfur Dioxide – 15-90%
Approvals
t CSA – C.22.2 No. 205-M 1983 (non-hazardous locations); CE (pending)
Warranty
t One year, including sensor
an
company
"