UTiFLEX ® Flexible Cable Assemblies High Vacuum/Altitude0 pages
UTiFLEX® Flexible
Cable Assemblies
High Vacuum/Altitude
Micro-Coax cable assemblies were tested for their ability to
withstand high vacuum/altitude conditions per MIL-STD 810,
Method 500.3, Procedure II.
The cable assemblies were placed in a vacuum chamber. The
insertion loss and return loss of the samples were measured
and recorded. Next, the vacuum chamber was evacuated to 1 x
10-5 torr or less. The insertion loss, return loss, and insertion
phase of each cable assembly was measured continually in
five minute increments for one hour. The cable assembly
performance did not change while in the vacuum chamber.
The chamber pressure was returned to ambient. The insertion
loss, return loss, and insertion phase of the cable assemblies
were measured again. The cable assembly performance did
not vary from the initial measurement. The cable assemblies
were removed from the chamber and visually inspected. No
physical change from before the vacuum environment
was evident.
office 610.495.0110 fax 610.495.6656 email sales@micro-coax.com
address 206 Jones Blvd, Pottstown, PA 19464 website micro-coax.com
L021R02