Continuon? 8U/CHS0 pages
THE
PRODUCT LINE
www.ibus.com
Continuon™ 8U/CHS
Netra™ Blade Compute Farm Platform
Ordering Information
Specifications
Continuon™ 8U/CHS
Standard Configuration includes :
• C0818D 8U System Platform
• Two CP1500 or two CP20xx SBC &
Rear I/O
• SPARC Processors
• Two PICMG 2.16 Switch Fabric boards
• 256MB ECC SDRAM
• Additional CPxxxx Computing Blades
---------------------------------------------Power Subsystem Options
PSU-AC
Four 200W N+1 AC power supplies
PSU-DC
Four 200W N+1 -48VDC power supplies
PIM-AC
Redundant AC isolated input modules
PIM-DC
Redundant DC isolated input modules
PIM-UPS
AC input module and an embedded UPS kit
Chassis
8U Height
• 14" x 17.1" x 12" (hwd) 356 x 434 x 304 mm
Control & Monitoring Options
IBC-2501
Chassis Management Controller, IPMI v.1.0
compliant Module.
Memory & Drive Options
From 18 GB to 36GB SCA drives
Up to sixteen IBC 280x server blades
Sun NetraTM CP 2060 SBC
• 500MHz Ultra SPARCTM IIe 64-bit processor
• Solaris 8 CD 6 Operating System
• Integrated 4-way 256KB L2 cache
• 512MB soldered on board ECC RAM
• 1MB on-board boot flash, 4MB user
programmable flash memory
• Sun Microcontroller, IPMI interface
• One PMC 32 bit 33MHz available
• Two RS-232C asynchronous serial ports
• Two USB ports
• Two 10/100 Mb/sec. Ethernet Interfaces
• Ultra-2 SCSI PMC with Rear I/O
• 1-Slot (4HP) x 6U CompactPCI Compliant
• CompactPCI Compliant Rear I/O Board
Supported SBCs
CP2040, CP2060, CP2080, CP1500
Two PICMG 2.16 Compliant Fabric Switch Boards
• Carrier-grade 24 port 10/100 + 2 ports Gb
switches
• Wire-speed layer 2/layer 3 (IP) switching
Backplane
• Integrated 8 + 8-slot CPCI segmented backplane
• System slots #1 and #9
• 14 full hot-swap I/O slots
• 7 + 7-slot segmented H.110 backplane
• Fully PICMG 2.16 PSB Compliant
Fail-Safe OPTICOOLTM Cooling
• Patented push-mix-pull cooling technology
• 8 + 2 fan, hot-swap cooling array in air intake
• Patented air flow mixing and directing tray
• 3 individually hot-swap blowers
• Optional blower and fan speed control with
I-Bus CMC
DC Power Subsystem
• 4 Hot-swap redundant -48VDC power supplies
• N+1 Redundant (N=3) 200W supplies
• Dual feed power inputs
• Input Voltage: -36 to 72 VDC auto-ranging
• Output Power: +3.3V@30A, +5V@25A,
+12V@5.5A, -12V@0.5A (each supply)
• Combined power of +5 and +3.3V not to
exceed 35A total per supply
Operating Environment
• Temperature: 0 to 40º C
• Humidity: 5% to 85% @40º C,
(non-condensing)
• Shock: 10g @11mS
• Vibration: 0.25G @2-100Hz, 1.5g@100-500Hz
Standards Compliance
• PICMG 2.0 R 3.0, PICMG 2.1 R 2.0,
PICMG 2.5 R 1.0, PICMG 2.9 R1.0,
PICMG 2.10 R 1.0, PICMG 2.11 R 1.0,
PICMG 2.16 R 1.0
• ESD: CE
• EMI: CE, FCC, UL/CUL
• Safety: UL/CUL, CE, CB
• NEBS
01-20-05 Rev. F
"