TURBINE FLOWMETERS BY
nnnnHOFFER
nnnnThe Turbine Flowmeter Company
nnnn^^^^^^^^= TECHNICAL DATA SHEET
nnnnWing Nut High Pressure (15,000 PSI)
nnnnTurbine Flowmeters lor Liquid Service
nnnnModel Number | Technical Data | |||||||||||||
Flowmeter Si Wing Nut Si | ze (Inches ze (Inches) | ) | (Refer Note 1) Linear Flow Range (US GPM) | (Refer Note 2) Bearing Types | (Refer Note 3 for more options) Standard Magnetic Pickup Coil | Wing Nut End Fitting - Savage (-S) or FMC (-F) Nuts & Seg- ments | Service Types | Nominal Pulses/Gallon 'K' Factor | Nominal Max. Freq. (Hz) | Length (inches) | ||||
Min. | Max. | |||||||||||||
Model HO | 2 | X | 1 | -4 -8.4 | -60 -84 | -CB -T | -1MX | -1502-S -1502-F | -H20 -CO 2 -CS | 670 650 | 670 910 | 12 | ||
Model HO | 2 | X | 1 V2 | -5 -8 | -175 -130 | -CB -T | -1MX | -1502-S -1502-F | -H20 -CO 2 -CS | 240 240 | 700 520 | 12 | ||
Model HO | 2 | X | 2 | -42 -65 | -420 -650 | -CB -T | -1MX | -1502-S -1502-F | -H20 -CO 2 -CS | 65 50 | 455 540 | 12 | ||
Model HO | 3 | X | 3 | -84 -105 | -840 -1050 | -CB -T | -1MX | -1502-S -1502-F | -H20 -CO 2 -CS | 55 50 | 170 875 | 11.38 | ||
FLOW RANGE (Note 1) Ranges are standard ranges — other ranges are available. Contact Hoffer Flow Controls Engineering. BEARING TYPE (Note 2) ( — CB) Hybrid ceramic, self-lubricating shielded ball bearings can be used on C02 and H20 and never on Cement/Sand Slurry. ( —T) Tungsten Carbide sleeve bearings can be used on H20 and CS and never on Liquid C02. PICKUP COILS (Note 3) (-1MX) One magnetic pickup coil. Optional ( —2MX180) Two magnetic pickup coils @ 1 80°. (—1 ISM)X Intrinsically Safe magnetic coil. ( —2ISM)X Two Intrinsically Safe magnetic coils. (—1ISMNE) One ISM ATEX coil with a standard 1 " coil riser less enclosure. ( —2ISMNE) Two ISM ATEX coils with a standard 1 " coil riser less enclosure. — (RPM )X Redi-Pulse magnetic pickup coil providing a user specified conditioned pulse output. See Redi-Pulse Technical Data Sheet for available options. — (DMX )X Intrinsically Safe Redi-Pulse magnetic pickup coil. See Intrinsically Safe Redi-Pulse Technical Data Sheet for available options. ENCLOSURES (-3/0) 3/0 Enclosure. ( —3B/0) 3/0 Enclosure with dome cover for style 1 signal conditioner to meet group B. Special Features (add at end of Model No.) ( — CE) CE mark required for Europe. FLOWMETERS ARE SUPPLIED WITH A 10 POINT CALIBRA TION AND WITH 'K' FACTOR TAG A TTACHED TO METER. * FLOWMETER LIFE IS LIMITED IN CEMENT/SAND SLURRY. CUSTOMER MUST SPECIFY MAXIMUM PARTICULATE SIZE ON CEMENT/SAND SLURRY APPLICATIONS. |
■
"