RL5017RN Single Output0 pages
Series RL5017RN
600W to 800W PFC POWER SUPPLY
FEATURES
Universal AC
l
Variable
l
input / full range
fan speed & low acoustical noise
Peak
l
power 900W within 500uS duty cycle
High
l
quality and reliable component usage
Optional
l
N+1 active current sharing
Approved
l
to UL/cUL/TUV/CB/CE and
class B emissions
Built-in
l
remote ON/OFF, remote sense,
current monitor
RoHS
l compliant
CB
SPECIFICATION
LED Display: Bi-color LED1 emit green for power on and
Input Fusing Protection: a T12A/250A fuse is inserted in
primary.
Over Power Protection: 110-140% of I-Max and auto-recovery.
Short Circuit Protection: Trip without damage and autorecovery.
Over Voltage Protection: Latching down will occur when output
voltage exceeds 130% and restart AC input supply after.
Remote ON/OFF : Designated as RSW on CN3, requires a low
signal to inhibit output.
Remote Sense: Designated as RS+ and RS- on CN3, total
voltage compensation with respect to the main output
(NOT available for current sharing models)
Over Temperature Protection: Unit protected from excessive
operating ambient temperature of 85°C and automatic
recovery.
Switching Frequency: PFC 40K~66KHz, PWM 55K~75KHz
Operating Temperature: 0°C to +70°C ambient, de-rating at
2.5% per degree from +50°C to +70°C.
emit orange when protection is enable or RSW is applied a
Storage Temperature: -20 to +85 degrees C
low signal.
Current Sharing: Designated as CSH on the CN3, optional
Operating Humidity: 5% to 90%RH, non-condensing
single wired for forced current sharing function and parallel
Vibration: 5 to 50HZ, acceleration ±7.35M/(SxS) on X, Y and Z
up to 4 units within 10% accuracy at full load.
Current Monitor (Option): Designated as CMN on the CN3
axis.
Input Voltage: 90 - 264VAC, full range
Input Frequency: 47-63Hz
Inrush Current: Max. 70A@230VAC with full load cold start.
PFC: 0.98 @ Vin: 230VAC full load.
Transient Response:
Returns to within 1% in less than 2.5mS for a 50% load
change and the peak transient does not exceed 5%.
Overshoot:
Turn off, when AC input gets 5% over nominal voltage.
Efficiency: 70% - 85% depends on model.
Turn-on Delay: 1.5 second max. at 230VAC
Hold up Time: 20mS min. at 80% of full load
Adjustability: Output user adjustable ±5% minimum
Power Good: PG on CN3 goes high 100-500mS after DC
regulation and low at least 1mS before loss of regulation
(open collector).
is a 0.5V to 3VDC output voltage to represent 0% to 100%
output current.
Input Voltage Protection: Power shut down under 80
±5VAC and recovered over 86VAC.
Storage Humidity: 5% to 95%RH, non-condensing
EMC: EN55022 class B conducted/radiated, EN 61000-3-2,
EN 61000-3-3, EN 55024 (IEC 61000-4-2, IEC 61000-4-3, IEC
61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC 61000-4-11).
Safety: EN/IEC/UL 60950-1
Leakage Current: Less than 1mA @ 264VAC.
www.hitekpower.com
"