Portable Vibration Shakers0 pages
HI 803/813 portable vibration shakers are designed to be used in the fi eld or shop to verify the performance of vibration transducers, connectors,
cabling, instruments or permanently installed condition monitoring systems. Both models are battery-powered, portable and feature a
built-in reference accelerometer and indicator with calibration traceable
to the National Institute of Standards and Technology (NIST).These shakers can easily check velocity transducers, accelerometers and non-contacting Eddy Probe displacement measurement systems. Simply attach the transducer to the shaker head (displacement probes require a mounting fi xture and target), set the shaker to a known vibration reference level, and verify readings. The reference test level can be set in acceleration, velocity, or displacement, English or Metric. >
HI 803/813 Shakers
nnHI 803HI 813 Specifi cationsFeatures Model HI 813
Actual precision vibration testers True and accurate testing of
vibration sensors >
Model HI 803
Օ NIST traceable calibration reference High-level vibration accuracy Rapid set-up for all vibration conditions Battery operated >
Battery TypeChargerFrequency RangeAcceleration Readout
(+ 1 digit)Velocity ReadoutDisplacement Readout
Maximum OutputCalibrationWaveform DistortionReference OutputMaximum Unsupported
LoadPhysical Size & WeightSensor Mounting Thread
English & Metric ReadoutIndicates Test SensorOutputInternal MemoryBuilt-In PrinterRS-232 Output Sealed, rechargableInternalSpecify 120 or 240 Vac10 to 10,000 Hz10 to 2,000 Hz, +.3 dB2,000 to 10,000 Hz, +1 dB10 to 500 Hz, +.3 dB25 to 200 Hz, +.3 dB10g at 100 Hz, 100 gram load(3g above 1,000 Hz)1g at 100 Hz, 750 gram loadNIST traceable standard<5% THD, 30 to 2,000 Hz50 mV/g750 grams, verticalor 500 grams, horizontal11ՔW x 7D x 10ԔH, 21 lbs.1/4-28 thd hole, 1/4 deepYesYes, normalized sensitivitymass loading compensation, phaseYes, stores test dataYes, thermal type, printscurrent or stored test dataYes, stored data transfer Sealed, rechargableInternal120 or 240 Vac25 to 10,000 Hz30 to 1,000 Hz, +.3 dB1,000 to 10,000 Hz, +1 dB30 to 500 Hz, +.3 dB30 to 100 Hz, +.3 dB10g at 100 Hz, 100 gram load(3g above 1,000 Hz)1g at 100 Hz, 750 gram loadNIST traceable standard<5% THD, 30 to 2,000 Hz50 mV/g750 gramsvertical or horizontal11ԔW x 7D x 10ԔH, 19 lbs.1/4-28 thd hole, 3/8 deepYesNoNoNoNo ԕ Variable frequency and adjustable vibration amplitudes Ability to take the calibration lab to the fi eldӔ >
SEISMIC PRODUCTS PORTABLESHAKERS PORTABLE SHAKERS
Applications
Loop checks of vibration monitoring systems Օ Verifi cation and testing of velocity transducers, accelerometers, eddy
current probes, etc. Troubleshooting of issues in vibration monitoring loopsՕ Calibration of portable vibration analyzers Conկ́ rmation of vibration alarms >
vibration@hardyinst.com www.metrix1.com Օ Sales & Service Tel: 281-940-1802 Fax: 713-559-9421 Օ 11/08 size="-2">