FRL units0 pages
AIR TREATMENT FOR AIR MOTORS
FRL units
Phone: +31 – 172 –426608
Fax: +31 – 172 426607
Website: www.globe-benelux.nl
e-mail: info@globe-benelux.nl
FRL UNITS FOR GLOBE AIR MOTORS
• Pre selected for use on GLOBE air motors;
• Standard with ATEX II cat. 2 G&D T5 for use in hazardous environments;
• All filters have a float type auto-drain;
• The FRL units are ready to mount and supplied with a pressure gauge.
Specifications
Model / ordering code GFRL3/8 GFRL1/2 GFRL3/4 GFRL1 GFRL11/2 GFRL2
Port size 3/8” ½” ¾” 1” 1½” 2”
Max. operating pressure 10 bar
Set pressure range 0,5 – 8,5 bar
Ambient and fluid temperature -5 to 60 ºC
Nominal filtration rating 5 ìm
Max. flow rate (L/ sec. free air) 25 50 75 165 200 265
Pressure drop (Äp) at 7 bar
(105 psi) and max. flow rate 1 bar 1,2 bar 1,4 bar 1,5 bar 1,3 1,1
Housing material Aluminium
Bowl material Polycarbonate
Weight (kg) 0,75 1,41 4,17 4,34 7,5 12
Recommended lubricant Class 1 turbine oil (ISO VG32)
FRL unit / air motor selection
Vane air motors Piston air motors
V1 V2 V4 V6 V8 V10 RM110 RM210 RM310 RM410 RM510 RM610
GFRL3/8 X X
GFRL1/2 X X
GFRL3/4 X X
GFRL1 X X X2 X
GFRL11/2 X2 X2 X
GFRL2 X2 X X
X2 = for maximum power at high speed of rotation.
Consult GLOBE Airmotors BV or their distributors for other motor types and models.