SOM 1000 pages
Waste Water Treatment Plant for
manually controlled treatment of water,
polluted with hydrocarbons, impurities,
paint or printing ink.
A mixer is activated and the splitting
agent, ENVIFLOC® 1010, is added.
The splitting agent is a mixture of
calcium, aluminium sulphate and
reaction substances.
The flocculation process will bind the
particles into larger sludge particles
which can be caught in a filter.
The mixer stops manually and after
some time of sedimentation, water
and sludge is led into filter bag.
6)
Consumption
3)
5)
780 x 440 x 1380 mm
150 L per day
230 V
ENVIFLOC® 1010
The water is pumped into the reactor
tank which contains approx. 75 L.
4)
Dimensions
Capacity
Required power
Splitting agent
The polluted water is collected in a
bulk after having passed an oil
separator if necessary.
2)
The plant is suitable where polluted
water reaches an average of up to
approx. 150 liters/day. The operation is
simple and quick.
1)
The sludge will gather in the filter
bag, where it will dry up after some
time so it can be discharged as solid
water. The clean water running out of
the bag can be led into the drain.
5-15 g/l (depending on
pollution load)
The plant is very useful to avoid leading polluted water to the surroundings and where discarding
costs are high. The plant is a perfect supplement to the closed-circuit washing units designed by
Flexo Wash.
Grenåvej 631 K • 8541 Skødstrup • Denmark • tel.: +45 86 99 36 31 • fax: +45 86 99 13 43
www.flexowash.com • info@flexowash.com