transmitters0 pages
Model
TRN
TRA
TROJ
TRC
TRB / TRBI
TRZ
TRU
TRIS
TRI
TRIL
TRIM
TRT
TRW
low-cost 2- or 3-wire smart low-cost 2-wire smart
temperature transmitter
transmitter
with universal
non-isolated / isolated input
triple-isolated smart
transmitter
with universal
input and output
infrared
temperature transmitter
with digital display
isolated smart
RS485 transmitter
with universal input
loop-powered
low-cost loop-powered
signal isolator
signal isolator
with T/C linearization blocks
universal 3-wire
DC signal isolator
low-cost 2-wire analog
AC/DC transmitter
for current transformers
high-protected
load-cell analog
transmitter
RTD: Pt100
T/C: B, E, J, K, N, R, S, T
RTD: Pt100, Pt1000,
PTC 1k, PTC 2k
T/C: B, J, K, R, S, T
linear: current, voltage,
resistance
RTD: Pt100, Pt1000,
PTC 1k, PTC 2k
T/C: B, J, K, R, S, T
linear: current, voltage,
resistance
infrared
thermocouple sensor
RTD: Pt100, Pt1000,
PTC 1k, PTC 2k
T/C: B, J, K, R, S, T
linear: current, voltage,
resistance
4…20 mA
externally powered loop;
input voltage drop: < 2.6 V
DC current, voltage,
or resistance
AC current 50/60 Hz
single load cell,
120...350 Ω
-50…600 °C
RTD: -200…600 °C
T/C: -40…1800 °C
temperature: -100…1800 °C
linear: 0(4)…20 mA,
0...100 mV, 0...10 V,
0...1 kΩ
temperature: -100…1800 °C
linear: 0(4)…20 mA,
0...100 mV, 0...10 V,
0...1 kΩ
-10…150 °C
temperature: -100…1800 °C 3.5…21 mA operating range 3.5…21 mA operating range
(abs. max. 50 mA)
linear: 0(4)…20 mA,
(abs. max. 50 mA)
0...100 mV, 0...10 V,
0...1 kΩ
0...5 mA, 0(4)…20 mA,
0...50 mV, 0...100 mV,
0...1/ 2/ 5/ 10 V,
-1...1 V, -10...10 V,
0...1 kΩ, other on request
0…1 A, 0…5 A,
other on request
(abs. max. 10 A)
1, 2, or 3 mV/V;
10 VDC excitation voltage
0.3% of span
0.2% of span or 0.2 °C
0.3% of span
0.3% of span
0.3% of span
2% of span
0.3% of span
0.1% of span
0.35% of span
0.1% of span
0.5% of span
0.15% of span
0.3% of span
within measurement error
within measurement error
within measurement error
within measurement error
within measurement error
within measurement error
within measurement error
within measurement error
within measurement error
0.5% of span
within measurement error
2-wire: 4…20 mA
4…20 mA
3-wire: 0…5 mA, 0(4)…20 mA,
0...1/ 2/ 5/ 10 V, 1...5 V, 2...10 V
4…20 mA or 20…4 mA
2-wire: 4…20 mA
4…20 mA or 20...4 mA
3-wire: 0(4)…20 mA, 0...10 V
0(4)…20 mA or 20…0(4) mA,
0...10 V or 10...0 V
0(4)…20 mA,
0…10 V
RS232 interface
RS485 serial interface,
2500 VAC for 1 min
4…20 mA or 20…4 mA;
3…22 mA operating range
4…20 mA;
3…22 mA operating range
0(1)…5 mA, 2...10 mA,
4…20 mA
0(4)…20 mA,
0...1/ 2/ 5/ 10 V, 1...5 V, 2...10 V
Sensor Failure
Reaction
< 3.5 mA or > 23 mA
< 3.5 mA or > 23 mA
< 3.9 mA or > 20.2 mA;
programmable
< 3.9 mA or > 20.2 mA;
programmable
< 3.8 mA or > 20.2 mA;
programmable
0 mA or > 20.2 mA;
programmable
4 mA
programmable
32 mA over-scale limit
< 2 mA
upscale or downscale,
selectable
3 mA and 28 mA
current limits
upscale or downscale
Isolation
none
none
none
none
none / 1500 VAC for 1 min
1500 VAC for 1 min
yes
> 1000 VAC for 1 min
up to 4000 VAC for 1 min
3750 VAC for 1 min
> 1000 VAC for 1 min
optional
none
Adjustment
"zero" and "span" trimpots
soldering jumpers,
"zero" and "span" trimpots
through
communication interface
through
communication interface
through
communication interface
through
communication interface
keyboard,
3-digit LED display
through RS485 interface
jumpers
"zero" and "span" trimpots
jumpers
"zero" and "span" trimpots
"zero" and "span" trimpots
Power Supply
2-wire: 12…36 VDC (T/C),
8…32 VDC (RTD, linear)
3-wire: 8…36 VDC
8…32 VDC
10...32 VDC
2-wire: 8...36 VDC
8…32 VDC ± 10%
3-wire: 9...36 VDC (current),
13...36 VDC (voltage)
230 VAC, 115 VAC, 24 VAC,
isolated 12...24 V
15…32 VDC
12...24 V
3…36 VDC input loop,
8…32 VDC output loop
passive:
3…36 VDC input loop,
8…32 VDC output loop
active: 24 VDC ± 10%
12...24 V
230 VAC, 115 VAC,
isolated 12...24 V,
8…32 VDC
15…35 VDC
Max. Line Load
750 Ω at 24V/20mA
800 Ω at 24V/20mA
800 Ω at 24V/20mA
800 Ω at 24V/20mA
750 Ω at 24V/20mA
600 Ω at 20 mA
750 Ω at 24V/20mA
32 transmitters in a network 620 Ω at 24V/20mA
620 Ω at 24V/20mA
620 Ω at 24V/20mA
800 Ω at 24V/20mA
750 Ω at 24V/20mA
Mounting
in-head, DIN-rail, or free
in-head, DIN-rail, or free
in-head or free
in-head, DIN-rail, or free
in-head, DIN-rail, or free
in-socket (DIN-rail)
free (DIN-rail)
DIN-rail
DIN-rail or free
DIN-rail or free
in-socket or DIN-rail
in-socket, DIN-rail, or free
free (DIN-rail)
Dimensions
in-head case: ø44x19 mm in-head case: ø44x19 mm in-head case: ø44x19 mm
DIN-rail case: 18x90x58 mm DIN-rail case: 18x90x58 mm box case: 80x80x60 mm
box case: 80x80x60 mm
box case: 80x80x60 mm
in-head case: ø44x19 mm in-head case: ø44x23 mm 35x78x91 mm
DIN-rail case: 18x90x58 mm DIN-rail case: 18x90x58 mm
box case: 80x80x60 mm
box case: 80x80x60 mm
80x92x65 mm
35x110x58 mm
DIN-rail case: 18x75x60 mm DIN-rail case: 18x90x58 mm socket case: 35x78x91 mm socket case: 35x78x91 mm 77x82x58 mm
box case: 80x80x60 mm
box case: 80x80x60 mm
DIN-rail case: 23x90x58 mm DIN-rail case: 35x110x58 mm without glands
box case: 80x80x60 mm
Connectivity
screw terminals
screw terminals
screw terminals,
interface connector
screw terminals,
interface connector
4-pin M12 connector
plug-in terminals
screw terminals
screw terminals
Miscellaneous
for T/C inputs
the output is proportional
to T/C voltage
10 RTD, 12 T/C subranges; software: "TraCon", free;
interface cable:
for T/C inputs
K1, K11U
the output is proportional
to T/C voltage
programmable
input/output conversion;
software: "TraCon", free;
interface cable:
K1, K2, K11U, K12U
software: "TraCon", free;
software: "TraCon", free;
interface cable:
interface cable:
K1(U), K2(U), K11U, K12U K2, K12U
7 selectable T/C
linearization ranges:
J (3 ranges)
and K (4 ranges)
negative output
input over-voltage
and over-current protection and custom specified
non-linear conversions
available
available
Description
low-cost 2- or 3-wire analog low-cost 2-wire analog
temperature transmitter
transmitter
with selectable input
with fixed input
Input
RTD: Pt50…Pt1000,
Cu50, Cu100
T/C: E, J, K, L, T, U
linear: current, voltage
Ranges
temperature: -50…1300 °C RTD: -50…500 °C
T/C: 0…1600 °C
linear: 0…max. 20 mA,
0...max. 10 V
Accuracy
0.3% of span
Non-linearity
0.3% of span
Output
2-wire programmable
RTD transmitter
for in-head mounting
RTD: Pt100
RTD: Pt100
T/C: E, J, K, L, N, R, S, T, U
screw terminals,
interface connector
11-pin socket base,
interface connector
suitable
software: "UniConf", free,
for remote measurement; and "PolyMonitor"
viewing angle: 7.3 °;
infrared emission spectrum:
5...15 μm
4…20 mA
externally powered loop;
input voltage drop:
> 2.6 V (passive),
< 2.6 V (active)
0(4)...20 mA,
0...10 V
open collector
socket case: 11-pin socket base socket case:11-pin socket base screw terminals
DIN-rail case: screw terminals DIN-rail case: plug-in terminals
box case: screw terminals
bare module
suitable
for installation
for general
inside current transformers weighing applications
available