Data Recording0 pages
Turn to the Experts
TM
Data Recording
DataCorder™
Features
Carrier’s DataCorder electronic trip data recorder, is integrated with the
MicroLink™ 3 controller. All control and recording functions are housed in
a single electronic module reducing demand for control box space and
simplifying spare parts concerns.
Flash memory. Data memory is retained without need
for battery backup.
With the DataCorder trip data recorder, you can record up to two years
of critical trip information and events. Actual duration of stored data is
dependent on operating configuration and recording options selected.
Data can be downloaded to any laptop, the DataReader™ retreival unit,
or via DataBank PC card technology. Using Carrier’s DataLINE™
diagnostic software, analysis and display can be presented in graphic
and tabular report format.
USDA Cold Treatment Option.
Controlling insects in perishable cargo shipped over long distances is
becoming increasingly important. Conventional insect-control
procedures are time-consuming and expensive. Environmental and
health concerns have led to restrictive legislation and, in some cases,
strict bans in chemical pesticides.
The Carrier DataCorder trip data recorder is USDA-certified to properly
record temperature events for pest-control cold treatment. This process
uses controlled temperature and time relationships to destroy insect
larvae in the cargo.
Accurate measurement and recording of cargo pulp temperatures over
the required time interval ensure that the process is successful. To
accomplish this, the DataCorder USDA provides connections at the side
of the reefer system – to plug in up to four remote probes that may be
inserted into the cargo at required locations. These probes measure
temperatures inside the cargo, and the DataCorder trip data recorder
logs those temperatures at intervals of one hour.
Real-time clock. Data and time are programmed into
DataCorder trip data recorder factory preset at
universal time (GMT), and user-changeable.
Memory card slot for software. System can be
downloaded via DataBank PC card technology.
Optional rechargeable power-up battery packs.
Unique permanent serial number in memory.
Versatile user-configurable operation.
USDA-certified.