C30 MicroTurbine Natural Gas0 pages
C30 MicroTurbine
Natural Gas
Robust power system achieves ultra-low emissions
and reliable electricity from natural gas.
•t
•t
•t
•t
•t
•t
•t
•t
Ultra-low emissions
One moving part – minimal maintenance and downtime
Patented air bearing – no lubricating oil or coolant
5 and 9 year Factory Protection Plans available
Remote monitoring and diagnostic capabilities
Integrated utility synchronization and protection(1)
Small, modular design allows for easy, low-cost installation
Reliable – tens of millions of run hours and counting
C30 MicroTurbine
Electrical Performance(2)t
High Pressuret
Onboard Gas Compressor Option
Electrical Power Outputt
30kWt
28kW
Voltaget
400 – 480 VACt
400 – 480 VAC
Electrical Servicet
3-Phase, 4 wiret
3-Phase, 4 wire
Frequencyt
50/60 Hz, grid connect operationt
50/60 Hz, grid connect operation
10 – 60 Hz, stand alone operationt
10 – 60 Hz, stand alone operationt
Maximum Output Currentt
t
46A, grid connect operationt
46A, stand alone operation(3)t
46A, grid connect operation
46A, stand alone operation(3)
Electrical Efficiency LHVt
26%t
25%
Fuel/Engine Characteristics(2) t
High Pressuret
Onboard Gas Compressor Option
Natural Gas HHVt
30.7– 47.5 MJ/m3t
30.7– 47.5 MJ/m3
(825 –1,275 BTU/scf)t
(825 –1,275 BTU/scf)
Inlet Pressure t
379 – 414 kPa gauge (55 – 60 psig)t
1.4 – 69 kPa gauge (0.2 –10 psig)
Fuel Flow HHVt
457 MJ/hr (433,000 BTU/hr)t
444 MJ/hr (420,000 BTU/hr)
Net Heat Rate LHVt
13.8 MJ/kWh (13,100 BTU/kWh)t
14.4 MJ/kWh (13,700 BTU/kWh)
Exhaust Characteristics(2)t
High Pressuret
Onboard Gas Compressor Option
NOx Emissions @ 15% O2(4)t
< 9 ppmvd (18 mg/m3)t
< 9 ppmvd (18 mg/m3)
NOx / Electrical Output
0.22 g/bhp-hr (0.64 lb/MWhe)t
0.22 g/bhp-hr (0.64 lb/MWhe)
Exhaust Gas Flowt
0.31 kg/s (0.68 lbm/s)t
0.31 kg/s (0.68 lbm/s)
Exhaust Gas Temperaturet
275˚C (530˚F)t
275˚C (530˚F)
(4)t
Reliable power when and where you need it. Clean and simple.
"