Solar Cell Spectral Response/QE/IPCE Measurement System0 pages
Ordering Information and Specifications
Solar Cell Scan 100 | 150W Xenon arc lamp for probe source, optical stability ^0.8%. Adjustable frequency optical chopper with control for insertion into or removal from optical path |
2. Probe light beam delivery: beam size is 3-10mm | |
3. Motorized control monochromator with triple-grating turret | |
4. Monochromatic light wavelength range : 300 - 2000 nm, with three gratings | |
5. Motorised filter wheel with order-sorting filters | |
6. Calibrated reference Si photodiode | |
7. Rack-mount computer with Microsoft Windows OS® | |
8. Wavelength accuracy : a) +0 3nm- 1200a/mm blaze 300nm Mst aratina') Cll — \J . \J 1 11 1 1 * 1 ^UUM' 1 1 II 1 1 g Y-t \f~*£—\j <Jwwl Mil t 1 Ol Ul aill IU 1 b) ± 0.6nm; 600g/mm, blaze 500nm (2nd grating) | |
9. <5 nm spectral bandwidth monochromatic light | |
10. Monochromatic light modulation: 4 - 400 Hz (adjustable) | |
11. Quantum Efficiency DC (DCS300PA) / AC (SR830) mode measurement | |
12. AC mode utilises the bias light source, optical chopper and lock-in amplifier detection | |
13. DC mode utilises a pre-amp with data acquisition system, DCS300PA, with dual channel inputs (sensitivity 100nA), and 16 bit analoque to diqital converter | |
14. Test fixture : 156mm x156mm | |
15. Single Spectral Response Scan less than 1 minute, IPCE measurement less than 5 minute (@ 5nm step from 300nm -1000nm) | |
16. Automatic operation, calibration and test report generation | |
QE-A1 | 150W Xenon Bias Liaht Source |
White bias light source, optical stability ^0.8% | |
Bias light filter holders for multi-junction measurement | |
QE-C1 | Specular reflective measurement capability, Si detector 300-1100nm |
QE-C2 | Integrating sphere diffuse reflectance measurement capability, Dual detector 300nm -1 ouunm |
v>4 1_ 1_> I | YV Qtano frvr OF 11nifrvrmit\/ eranninn 1 ^fimm vl ^Rmm /\ 1 OlaUC 1 Ul W1_ U1 1II Ul 11 11 Ly oUal llllliy, liJUIIIIIIAIiJUIIIIII |
QE-F1 | Vacuum sample clamp test fixture, 156mm x156mm |
QE-F2 | Thermoelectric temperature control @ 25 °C for QE-F1 |
QE-F3 | 30x30mm Thermoelectric control sample holder temperature Control 5-40 °C |
—
Zolix Instruments Co., Ltd. ,
Add: No. 5 Street South BaLiQiao Tongzhou District
Beijing China (101149)
TEL:+86 10 60535165
FAX: +86 10 60539014
http://www.zolix.com.cn
Email: info@zolix.com.cn
h ttp://www.zolix. com. cn
Zolix
Solar Cell ScanlOO
Solar Cell Spectral Response/QE/IPCE Measurement System
Full QE/IPCE measurement solution with professional team support
Full solar spectrum simulation (300-2000nm) ready for NIR PV device study!
Vertical beam path optimized for the measurement of plane PV devices
Adjustable collimating bias beam path suitable for tandem PV devices
AC mode suitable for Si-base, CdTe, CIGS, GaAs PV devices
DC mode suitable for Slow Response DSSC and Organic PV devices
Temperature Controlled Stage from 5-40°C
XY motorised stage for large PV device QE uniformity scanning
Specular and diffuse reflection measurement capability
Easy-to-use turn-key design _
ZOLIX INSTRUMENTS CO.,LTD.
"