Series Datasheet – 528 Optocouplers
528 Series
Optocouplers
Features: Optocoupler for Intrinsically Safe Circuits
Applications: Electronics for Mining, Test & Measurement, Automation Technology
Markets: Oil & Gas Production, Refinery, Mining, Medical, Test and Measurement, and others
528-00-0
Part Description:
Customer Options
Coupler Characteristics
Unit
Isolation Voltage Input / Output (min.)
Current Transfer Ratio (min.)
Ic/If CTR (If = 10mA)
Turn On Time (typ.)
10,000
VDC
0.9
5.5
μsec
4.2
μsec
Collector-Ermitter Voltage (max.)
70
VDC
Collector Current Ic (max.)
50
mA
Creeping Distance (min.)
42.0
mm
Air Path Input / Output (min.)
42.0
mm
Ton
Turn-Off Time (typ.)
Toff
Insulation Distance Ermitter-Detecto (min.)
5
mm
Insulation Resistance Input / Output (min.)
1012
Ohm
50
kHz
Transmission Frequencies (typ.)