t056 TRADNT Net Solar Radiation Tansducer0 pages
t056 TRADNT
t056 TRADNT.doc (02)
mercoledì 12 settembre 2012
Tutte le informazioni contenute in questo documento sono quelle attuali al momento della stampa, Siap+Micros S.r.l. si riserva il diritto di cambiarle senza alcun preavviso.
All the information content in this document are the current available at the printing phase. Siap+Micros reserve the rights to change the specifications without any advance notice.
Trasduttore di Radiazione Solare Netta
Net Solar Radiation Tansducer
Principio di Misura: la misura viene effettuata tramite due
sensori contrapposti che rilevano la differenza tra la
radiazione diretta e quella riflessa dal suolo. Lo strumento
è costituito da due termopile che si riscaldano
proporzionalmente alla radiazione solare incidente,
assorbita da una speciale vernice nera che ricopre la
superficie delle termopile stesse. Le zone sensibili dello
strumento sono protette da cupole realizzate in materiale
plastico con trasmittanza nell’infrarosso.
Sensori Intelligenti : il trasduttore appartiene alla famiglia
dei sensori intelligenti in quanto dotato di microprocessore
interno che esegue tra le altre funzioni di: controllo del
corretto funzionamento, pre-elaborazione dei dati,
conversione A/D dei segnali elettrici, ecc. Queste
caratteristiche garantiscono un eccellente accuratezza ed
elevata affidabilità dei dati.
Certificato di Calibrazione: Il sensore può essere
corredato di certificato di calibrazione Siap+Micros oppure
da certificati rilasciati da altri laboratori esterni (SIT,
Colonnetti, ecc.).
Materiali e norme Internazionali: : Il corpo del sensore è
in lega di alluminio anticorrosione e viterie in acciaio inox.
Il trasduttore è conforme a quanto previsto nella normative
Europea su EMC, è protetto contro le sovratensioni e
risponde
pienamente
alle
prescrizioni
dell’OMM
(Organizzazione Meteorologica Mondiale).
Measure principle: The measures are performed by
means of two opposing sensors that calculate the
difference between the direct sun radiation and the
reflected ground radiation. Each sensor is formed by a
transducer that warms up as a function of received solar
radiation, adsorbed through a special black varnish
covering the surface of measuring element. The sensors
are protected with special plastic domes with infrared
transmittance.
Intelligent sensor: The transducer belongs to the
intelligent sensor family as based on a internal microprocessor chip that execute among other functions: the
correct control functioning, data pre-processing, electrical
signal A/D conversion etc. This characteristics warranty
excellent accuracy, long-term stability and high data
reliability.
Laboratory calibration: the sensor can be supplied with a
Siap+Micros calibration certificate or with calibration
certificates issues by
external primary metrological
services (SIT, Colonetti, ecc).
Housing materials and International standards: the
transducer body is made of anodized aluminum corrosionproofing with stainless steel screws. The transducer
complies with CE EMC standards, it’s protected against
over tensions and is fully compliant within the WMO (World
Meteorological Organization) standards.
Codici d’ordine
Ordering codes
Descrizione
Codice / Code
Description
Trasduttore Radiazione solare netta a termopila
uscita 4÷20 mA
t056a TRADNT-I
Net Solar Radiation Transducer,
output 4÷20 mA
Trasduttore Radiazione solare netta a termopila
uscita 0÷2 Vdc
t056b TRADNT-V
Net Solar Radiation Transducer,
output 0÷2 Vdc
Trasduttore Radiazione solare netta a termopila
uscita RS485
t056c TRADNT-S
Net Solar Radiation Transducer,
output RS485