XHF gen with X trans (500 - 1500 GPM)0 pages
U
N
I
V
E
R
S
A
L
Maximum flow ranges fromt
Max pressuret
Temperature ranget
®
F L O W
4-200 GPM (22-750 LPM)
300 PSI (20 Bar)
32-210°F (2-99°C)
CP-V9
Profinet
CoolPoint
™
M O N I T O R S
UNIVERSAL
Flow Monitors
®
Vortex Shedding
Flowmeter
Description
These vortex shedding flowmeters are designed for
water and low viscosity fluids like coolant with the
following features.
·t PROFINET protocol for flow rate, set point and
status
·t Digital LCD display of flow, set point and status.
·t LED status lights
·t No moving parts to clog or wear
Material Specifications
Flow bodies of brass or 316 Stainless Steel with
PVDF sensors and Viton® seals standard. PEEK
sensors used for high temp for fluids above 150° F.
Instrument Specifications
•t Flow
t Visual readout: 4 digit LED
t Deadband for Alarm: 5% of full scale (maximum
flow)
t Accuracy: ±2% of full scale (maximum flow).
t Repeatability: ±.25% of indicated flow.
t Turndown (ratio of max to minimum flow rates):
t 10:1 at all temperatures and 20:1 available
t optionally for standard temperatures.
•t Pressure
t 300 PSIG (20 Bar) operating pressure
•t Response time
t 60 ms flow status, 450 ms for change in flow
•t General
t Fluid temperature limits: 35-150° F (2-66° C)
t standard, 150-210° F (66-99° C) optional 3 wire
t units only.
•t Pipe Connections:
t Female NPT, BSPP & BSPT
•t Back pressure of 10 PSIG required
Profinet
•t 100 Mbit/s
•t Dual RJ45 ports
•t Fast Start Up (FSU) compatible