PMIB3 Magnetic Scale0 pages
PMIS3 POSIMAG®
Magnetic Scale Position Sensor
Very compact sensor for industrial applications
Sensor head PMIS3
• t Non-contact, no wear
•t High velocity
•t Robust shielded metal enclosure
•t Protection class IP67
•t Incremental encoder output A/B/Z
•t Signal processing as usual with encoders
• t Reference pulse and end position signal
•t Indicator for velocity/position errors
A POSIMAG measuring system consists of the
sensor head PMIS3 and the magnetic scale PMIB3
with the same magnetic period.
Output
Incremental encoder output A/B with differential
push-pull output, TTL/RS422 or HTL compatible
Excitation voltage
10 ... 30 VDC or 5 VDC ±5 %
Excitation current
Specifications
50 mA to 300 mA, depending on pulse frequency,
cable length and load
Magnetic period of the sensor
2 mm
5 mm
0.1 ... 0.8 mm
0.1 ... 2 mm
±1 mm
±1 mm
15 µm ± 40 µm/m
30 µm ± 40 µm/m
Guided spacing between sensor and mag. scale (xz)
Side tracking tolerance of the sensor
Linearity (sensor with mag. scale PMIB3)
Repeatability
± 1 digit
Resolution with ext. times 4 counting mode [µm]
PMIS3
—
10
20
50
10
25
50
125
0.8
Max. velocity with fp=50 kHz [m/s]
(20 kHz: x 0.4; 10 kHz: x 0.2)
Order code PMIS3
± 1 digit
5
1.6
3.2
8
1.6
4
8
20
—
—
—
—
KHZ—
M—
Model name
Magnetic period
20 = 2 mm / 50 = 5 mm
Resolution (in µm) with times 4 counting mode
Mag. period 2 mm: 5 / 10 / 20 / 50
Mag. period 5 mm: 10 / 25 / 50 / 125
Max. pulse frequency (in kHz, standard 50 kHz)
50 / 20 / 10
Output
HTLtt
= HTL output with excitation 24 VDC, output 24 V
TTLtt
= TTL output with excitation 5 VDC, output TTL/RS422
TTL24Vt
= TTL output with excitation 24 VDC, output TTL/10 mA
Reference pulse/ end position signal/ status signal
Z0tt
= A/B w/o reference pulse / Z1 = A/B with reference pulse Z
Z2tt
= A/B with end position signal / *Z3 = A/B with reference pulse
tt
and status signal
tt
(Option Z3 only for non-diferential output, single ended)
Cable length (in m, standard 2 m)
Connection
Stt
= Cable output, open end
P / P15t
= SUB-D connector at the cable end: P = 9 pins; P15 = 15 pins
Order example: PMIS3 - 50 - 25 - 50KHZ - HTL - Z1 - 2M - S
6
t
CAT-PM--E-04tt
Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.com
ASM GmbHt
"