MR-J3-B Safety Integrated AC Servo Amplifier Brochure0 pages
Changes for the Better
MITSUBISHI
ELECTRIC
General-Purpose AC Servo
MELSERVO-J3
Drive Safety integrated AC servo amplifier
<MR-J3-DS 0.1 kW to 55kW>
Safety logic unit <MR-J3-D05>
The MR-J3-DS Drive Safety integrated AC servo amplifier (SSCNET
IE compatible) and MR-J3-D05 safety logic unit are newly added to
the MELSERVO-J3 series.
Safety functions of the MR-J3-DS and MR-J3-D05 are certified for
IEC/EN 61508 SIL 2, EN 62061 SIL CL 2 and EN ISO 13849-1 PL d
(Category 3) by a Certification Body (TUV Rheinland).
As a safety function, MR-J3-DS has an integrated Safe torque off
(STO) function. Safe stop 1 (SS1) function can be realized by
combining MR-J3-DS with MR-J3-D05. These functions contribute
to improvement of safety in the user's system, making it easy to
obtain third-party certification.
If MR-J3-DB is currently used in a user's system, it can be easily
replaced by the MR-J3-DS since both of these servo amplifiers use
the same cables and connectors. Also, the MR-J3-DS lineup
contains fully closed loop control system versions.
■ Features
• MR-J3-DS and MR-J3-D05 meet IEC/EN 61508 SIL 2, EN 62061 SIL CL 2 and EN ISO 13849-1 PL d (Category 31 Only the
Safe torque off (STO)*1 function is integrated into the MR-J3-DS. The MR^J3-D05 contains both Safe stop 1 (SS1) and Safe
torque off (STO)*1 functions.
• User's system can satisfy stop category 0*2 by using the Safe torque off (STO) function*1.
• User's system can satisfy stop category 0 and 1*2 by using the Safe torque off (STO) and Safe stop 1 (SS1) functions*1.
• Mounting, wiring and connectors of MR^J3-DS are compatible with those of MR-J3-DB. Thus, MR-J3-DB can be easily
replaced by the MR-J3-DS using the existing connections. The safety functions are accessible via the new CN8 connector on
the MR-J3-DS.
*1. Refer to EN IEC 61800-5-2 for details of Safe torque off (STO) and Safe stop 1 (SS1) functions.
*2. Refer to EN IEC 60204-1 for details of stop category.
System Configurations (example of using 2 systems of STO and SS1 functions)
(Note 5)
STO switch
IbrA-axis (Note 4)
Safety logic unit
MR-J3-D05
► ToEM2ofCN3(A-axis)
[Note 2)
STO start/reset button
switch for A-axis
STO switch
lbrB-axis(Note4)
► To EM2 of CN3 (B-axis)
[Note 2) L
STO start/reset button
switch for B-axis
Power supply
0—
STO cable
MR-D05UDLDM
(for A-axis)
STO cable
MR-D05UDLDM
(for B-axis)
Attach a cap to
the unused
connector.
Notes: 1. For prevention of electric shock during maintenance or for protection during servo amplifier fault, be sure to connect a magnetic contactor
(MC) between the main power supply and L1, L2 and L3 of the servo amplifier or converter unit.
2. Connect the STO switch signal and forced stop 2 (EM2) signal in connector CN3 of the servo amplifier in addition to the connection with
the safety logic unit (MR-J3-D05).
3. Safety logic unit (MR-J3-D05) has 2 independent systems (A-axis and B-axis).
4. All safety-related components such as relays, sensors, etc., must meet the applicable safety standards.
5. Perform risk assessment and safety level certification on the entire machine/system.
"