GAS ENGINE-GENERATOR SET AIR CHARGE-AIR COOLING0 pages
A TOGNUM GROUP BRAND
GAS ENGINE-GENERATOR SET
AIR CHARGE-AIR COOLING
355 kWe /60 Hz /Prime
208 - 600V
(Reference GS400-6S for Standby Rating Technical Data)
SYSTEM RATINGS
Prime (NG)
GP355N6SGA
GP355N6SPA
GP355N6SJA
GP355N6SRA
GP355N6SNA
Voltage (L-L)
Phase
PF
Hz
Natural Gas
Ratings: Amps
Natural Gas
Ratings: kW/kVA
skVA@30%
Voltage Dip
Generator Model
Temp Rise
Connection
240V**
1
1.0
60
208V**
3
0.8
60
240V**
3
0.8
60
480V**
3
0.8
60
600V**
3
0.8
60
1458
1232
1068
534
427
350/350
355/443
355/443
355/443
355/443
760
574RSL4037
105 °C/40 °C
1500
572RSL4029
105 °C/40 °C
1500
572RSL4029
105 °C/40 °C
1500
572RSL4029
105 °C/40 °C
1450
572RSS4272
105 °C/40 °C
12 LEAD ZIG-ZAG
12 LEAD LOW WYE
12 LEAD HI DELTA
12 LEAD HI WYE
4 LEAD WYE
** UL 2200 Oered
CERTIFICATIONS AND STANDARDS
//
Engine-generator set is designed and manufactured
in facilities certied to standards ISO 9001:2008 and
ISO 14001:2004
//
UL 2200 / CSA – Optional
– UL 2200 Listed
– CSA Certied
//
Performance Assurance Certification (PAC)
- Engine-Generator Set Tested to ISO 8528-5 for
Transient Response
- Veried product design, quality and performance integrity
- All engine systems are prototype and factory tested
//
Power Rating
- Accepts Rated Load in One Step Per NFPA 110