Alarm'Box0 pages
Alarm’Box
A.M.I.
Indicator Display and Alarm Unit
with Battery
rrant
y
ye
y
The ALARM’BOX allows clustering at one single point for
effective protection and easy maintenance for industrial
and administrative sites :
- Important indicator displays : Including In service/Out of
service, Run/Stop, and levels, ...
- Technical alarms : Including trip-outs, temperature
alarms, levels, and overspeeds, ...
2 rs
a
wa
wa
www.ami-control.com
rrant
- Each way can be shown on simple indicator displays or in
alarm mode.
- High luminosity, long life 5x10mm LED display.
- Possibility of choice of one colour per way.
- LEDs can be clustered according to the monitoring
elements.
example : 3 ways for Run/Stop/Fault.
The ALARM’BOX was developed according to the strictest
industrial standards.
8 to 96 channels modulation
(1 to 3 stages)
280
For each channel :
- Data storage, blinking, operator acknowledgement on selected «Alarm»
ways.
- Fixed simple display on selected simple indicator display ways.
- NO/NC selection.
- 0-1min and 1-10min WLPH GHOD\ ¿OWHULQJ LQSXW SURFHVVLQJ.
- Remote input inhibiting.
- 6HOHFWLRQ RI ZD\V WR ©V\QWKHVLVª RXWSXW JHQHUDO DODUP IRU UHPRWH
reporting.
One cabinet includes :
- WR VWDJHV ,3 ZDOO¿[HG FDELQHW ZLWK GRXEOH
insulation.
- Front buttons for «Test» and «operator acknowledge».
- A certain number of 8 inputs cards.
- 1 internal buzzer and one output contact for
external sound alarm.
- 1 «General alarm» output contact.
- 1 «power supply alarm» output contact.
- 1 x 230Vac power supply.
- Charger with battery for autonomous operation.
145
430
Wiring to be done :
It is fully pre-wired. It is enough to connect up :
- Two leads for 230Vac power supply.
- Two leads per «contact» input.
145
MODELS :
Number
of ways
Type
12Vdc without
battery
230Vac without
battery
230Vac with
battery
Autonomy
standard *
8 inputs
16 inputs
24 inputs
32 inputs
1 stage
AJ1900-01-11
AJ1900-01-12
AJ1900-01-13
AJ1900-01-14
AJ1900-05-11
AJ1900-05-12
AJ1900-05-13
AJ1900-05-14
AJ1900-05-11B
AJ1900-05-12B
AJ1900-05-13B
AJ1900-05-14B
85
76
67
60
40
48
56
64
inputs
inputs
inputs
inputs
2 stages
AJ1900-01-21
AJ1900-01-22
AJ1900-01-23
AJ1900-01-24
AJ1900-05-21
AJ1900-05-22
AJ1900-05-23
AJ1900-05-24
AJ1900-05-21B
AJ1900-05-22B
AJ1900-05-23B
AJ1900-05-24B
45 h
42.5 h
40 h
37.5 h
72
80
88
96
inputs
inputs
inputs
inputs
3 stages
AJ1900-01-31
AJ1900-01-32
AJ1900-01-33
AJ1900-01-34
AJ1900-05-31
AJ1900-05-32
AJ1900-05-33
AJ1900-05-34
AJ1900-05-31B
AJ1900-05-32B
AJ1900-05-33B
AJ1900-05-34B
31
30
29
28
8 inputs
additionnal
card
h
h
h
h
580
h
h
h
h
AJ1900-01-10C
Additional 8 inputs card with connector for relay card : AJ1900-01-10CA
* standard autonomy : ALARM’BOX with batteries are delivered with 12V/7Ah battery as standard.
7KH DXWRQRPRXV WLPH LV WKDW ZKLFK DOORZV WKH IROORZLQJ WHVW DIWHU K EDWWHU\ FKDUJH PDLQV VXSSO\ SUHVHQW
- 8QLW UXQQLQJ RQ VWDQGE\ QR PDLQV VXSSO\ ZLWK LQGLFDWRU GLVSOD\V RU DODUPV
- Detection and noting alarm for maximum 1 minute at end of autonomous time.
30
145
Alarmbox-EN004-28-02-2012
Technical
Alarm
306