VMS Series0 pages
Vacuum Section / Section Four
nnnnVMS Series Smart Pump
nnnnVacuum Management System
nnnnDual Channel Vacuum Generator
nnnnVMS21 10 & VMS2310 w/DeviceNet
nnnnFeatures and Technical Data
nnnnFEATURES
nnnn► Electro-pneumatic vacuum management
nnnnsystem with everything to develop and
nnnncontrol vacuum in one product.
nnnn► Dual channel vacuum control.
nnnn► Twin multi-stage vacuum generators.
nnnn► Selectable vacuum level.
nnnn► Automatic vacuum level monitoring.
nnnn► Part present level selection and
nnnnoutput signals.
nnnn► Direct connection to PLC.
nnnn► Forced blow-off assures part separation
nnnnQuick change filter and silencer.
nnnn► Solenoid manual overrides.
nnnnMODELS AVAILABLE
nnnn► VMS 2110 Vacuum level settings and
nnnnpart present switchpoints are independently
nnnnadjustable. Both functions are controlled
nnnnby two five-position switches on the
nnnncontrol module. One switch controls the
nnnnvacuum levels for both channels, the other
nnnncontrols the part present switchpoints for
nnnnboth channels.
nnnnVMS 2310 Norgren Automotive also
nnnnoffers a DeviceNet compatible Smart
nnnnPump. Please Contact your Norgren
nnnnAutomotive sales representative for
nnnnmore information.
nnnnMATERIALS AND WEIGHT
nnnnBody: Aluminum
nnnnSeals: Viton®, polyurethane,
nnnnBuna-N
nnnnWeight: 10 lbs [4.5 kg]
nnnn■67.7 -kPa]
nnnn1/min @ 4.3 bar]
nnnnTECHNICAL DATA
nnnnVacuum Level Range:
nnnn12.0 - 20.0" Hg [40.6 ■
nnnnVacuum Flow:
nnnn16 SCFM @ 62 psig [453
nnnnEvacuation Response Time:
nnnn1 ft3 to 20" Hg in less than 20 seconds
nnnn[28 liters to 51 -kPa in less than 20 seconds]
nnnnVacuum Hysteresis Range:
nnnn0.5-2.0" Hg [1.7-6.8 -kPa]
nnnnVacuum Status Indicators:
nnnnOne LED per solenoid to indicate active valve
nnnnOne LED per channel to indicate part present
nnnnAir Consumption:
nnnn20 SCFM @ 50 psig [566 1/min @ 3.4 bar] (both channels operating)
nnnnSupply Pressure Range:
nnnn45 - 100 psig [3.1 -6.9 bar]
nnnnFluid (Air Preparation):
nnnnLubricated or Non-Lubricated, Air filtered to 40 micron
nnnnOperating Temperature:
nnnn32 - 122° F [0 - 50° C] (Air supply must be dry enough to
nnnnavoid ice formation at temperatures below 35° F [2° C].)
nnnnPort Specifications:
nnnnSupply Pressure Ports: 2 Places - 1/4" NPT/BSPT
nnnnVacuum Ports Channel 1 & 2: 1 Place - 1/4" NPT/BSPT
nnnn2 Places-3/8" NPT/BSPT
nnnnNote: See order information to specify NPT or BSPT porting.
nnnnPower Required:
nnnnSupply Voltage
nnnnSupply Power
nnnnControl Inputs - 1 control and 1
nnnnOptical Isolation
nnnnMin. Turn On Voltage
nnnnMax. Turn Off Voltage
nnnnnput Impedance
nnnn1 20 VAC Models 24 VDC Models
nnnn120 VAC 50/60 Hz 24 VDC
nnnn12 Watts 12 Watts
nnnnforced blow-off per channel (sourced):
nnnn1500 V 1500 V
nnnn80 VAC 17 VDC
nnnn35 VAC 9 VDC
nnnn34 K Ohms 6.5 K Ohms
nnnnClick logo to return home
nnnnVMS Smart Pump Vacuum Management
nnnn53
"