TGS Series Toroidal Grating Spectrograph0 pages
TGS Specifications
TGS300
Optical design
0,16
300 mm
0,14
f/30
0,12
Focal length
Aperture
Optic coating
Pt (Au in option)
Deviation angle
137°
Vacuum
10-6 mbar (HV version) or
10-9 mbar (UHV version)
Pumping flange
DN63LF (DN63CF)
Entrance port
Absolute Efficiency
Fixed toroidal VLS Grating
(single optic)
541 00 210
Pt
TGS-Series
0,10
Au
0,08
0,06
541 00 220
0,04
541 00 200
Micrometric slit (10 µm to 2 mm)
Adjustable CCD port
0,00
Toroidal Grating Spectrograph
0,02
Exit port
Entrance flange
0
10
20
30
40
Exit flange
DN100CF
Software
60
70
80
90
100
110
120
130
140
150
160
170
180
Theoretical Absolute Efficiency
HORIBA Scientific software
PC Interface
50
Wavelength
DN40 KF
Coming from Synchrotron technologies
RS232 - USB2
313
137
218
321
565
Adjustable
CCD Port
IN
137°
362
613
TGS300 in HV version, two gratings on slider
638
IN
137°
366
TGS300 in UHV version, two gratings on slider
www.horiba.com/scientific
info.sci@horiba.com
France:t HORIBA Jobin Yvon S.A.S., 16-18 rue du Canal, 91165 Longjumeau cedex - Tel: +33 (0)1 69 74 72 00 - Fax: +33 (0)1 69 09 07 21 - Email: info-sci.fr@horiba.com
USA:t
HORIBA Instruments Inc., 3880 Park Avenue, Edison, NJ 08820-3012 - Toll-free: +1-866-562-4698 - Tel: +1 732 494 8660 - Fax: +1 732 549 5125 - Email: info-sci.us@horiba.com
Japan:t
HORIBA Ltd., Tokyo Branch Office, 2-6, KandaAwaji-cho, Chiyoda-ku, Tokyo 101-0063, Japan - Tel: +81-(0)3 6206 4721 - Fax: +81 (0)3 6206 4730 - Email: info-sci.jp@horiba.com
Germany:t HORIBA Jobin Yvon GmbH, Hauptstrasse 1, 82008 Unterhaching - Tel: +49 (0)89 4623 17-0 - Fax: +49 (0)89 4623 17-99 - Email: info-sci.de@horiba.com
Italy:t
HORIBA Jobin Yvon Srl., Via Cesare Pavese 21, 20090 Opera (Milano) - Tel: +39 2 5760 3050 - Fax: +39 2 5760 0876 - Email: info-sci.it@horiba.com
UK:t
HORIBA UK Ltd., 2 Dalston Gardens, Stanmore, Middlesex HA7 1BQ - Tel: +44 (0)20 8204 8142 - Fax: +44 (0)20 8204 6142 - Email: info-sci.uk@horiba.com
China:t
HORIBA (China) Trading Co. Ltd., Unit D 1F, Bldg A, Srynnex International Park, No. 1068 West Tianshan Road, Shanghai 200335 - Tel: +86 (0)21 6289 6060 - Fax: +86 (0)21 6289 5553
t
Email: info-sci.cn@horiba.com
Brazil:t
HORIBA Instruments Brasil Ltda., Rua Presbítero Plínio Alves de Souza, 645, Loteamento Polo Multivias, Bairro Medeiros, Jundiaí / SP, CEP 13.212-181 - Tel: +55 (0)11 2923 5400
Fax: +55 (0)11 2923 5490 - Email: infocientifica.br@horiba.com
Other:t
Tel: +33 (0)1 69 74 72 00 - Email: info.sci@horiba.com
Explore the future
Automotive Test Systems | Process & Environmental | Medical | Semiconductor | Scientific
This document is not contractually binding under any circumstances - Printed in France - ©HORIBA Jobin Yvon 05/2014
Adjustable
CCD Port
137
218
332
313
523
590
Compact
Stable
Robust
No Motor
High Troughput
Explore the future
True Flat Field
Fixed position
Grazing Incidence
Automotive Test Systems | Process & Environmental | Medical | Semiconductor | Scientific
"