تماس با ما
وب سایت در حال به روز رسانی است. از شکیبایی شما سپاسگزار هستیم.

منابع یابی و خرید تجهیزات صنعتی

محصولات
محصولات
سازندگان
کاتالوگ
فیلم

 (ویژه صنایع و کارخانجات )

خدمات خرید ، حمل ، ثبت  سفارش ، ترخیص و تحویل هر گونه کالای صنعتی از اروپا ، چین ، ترکیه  و امارات متحده عربی
لطفا جهت خرید ، حمل ، ترخیص و تحویل هر گونه کالای صنعتی در هر نقطه از دنیا با ما در تماس باشید .
ایمیل sales@meshgad.com

تماس : ۸۸۸۷۱۸۰۸ - ۸۸۸۷۱۸۷۵ - ۸۸۶۵۶۴۷۱

  • 1
  • 2
  • 3
  • 4
  • 6
LOADING

VA-3000 Series0 pages

نسخه متنی
"

VA-3000 Series / VS-3000 Series 06
Wide Variety of Standard Features and Functions as well as Optional Features.
Allow the VA-3000 to be Configured to Meet the Requirements of Any Application.
Standard functions configured prior to shipment include:
Atmospheric Pressure Correction:
Select 0-1VDC or 4-20 mA for each of two channels per module
VA-3000 Series
Other Optional Features:
Output:
Multi-Component Gas Analyzer
The pressure compensation function corrects the output signal from the NDIR
and MPA O2 modules for changes in sensitivity caused by changes in the
atmospheric pressure since the instrument was last calibrated with a cylinder
calibration gas. Galvanic, PMA and Zirconia O2 modules and the CLD module
do not have pressure compensation. This option is useful if you desire the best
possible accuracy over a period of time when you will not calibrate the
instrument with cylinder gas.
Communication Ports:
One of two RS-232 may be changed to RS-485
Automatic Calibration:
Activate this function to allow the instrument to reset the zero and span
calibrations when the instrument is manually or remotely put in the calibrate
mode.
Select Automatic Range Change:
Allows the user to set a point where the analyzer will automatically change
from the measurement range it is currently on to the next highest or lowest
range available in the analyzer module depending on whether the measured
concentration is increasing or decreasing.
Select Negative Display:
Negative measurement value means you will never see any value on the
screen less than 0.000.
Select O2 Correction:
If an O2 module is installed in the instrument case with other modules such as
CO and NOx and if this function is activated, the measured values for CO and
NOx will be corrected for dilution based on the measured O2 concentration in
accordance with US EPA procedures. The instrument will have analog and
digital (if communication options are installed) outputs for both the raw CO and
NOx values as measured and the corrected values.
Select the Concentration HOLD Function:
If this function is activated, when the instrument is put into the zero or span
calibration mode, the concentration values indicated at the analog outputs and
any digital outputs (if additional communications options are installed) will be
held at the concentration value last measured before the instrument mode was
changed.
Set Alarms for the Gas Concentration:
There are two alarm points that can be set for each analyzer module. These
can be set to alarm at a Low (zero) and a High value, or at a High and a Higher
value. The alarm will show on the instrument front panel screen and will
transmit information via the RS-232 port and if the optional PIO board is
installed, contact closures are also available.
Select Memory of Calibration and Alarm History:
The processor in the instrument stores the zero and span calibration
coefficients for each module installed in the case for 15 days. This information
can be displayed on the front panel to indicate if there is a significant trend in
calibration shift that would indicate that there might be a problem with the
analyzer module. The processor also stores the last 30 analyzer alarms that
occurred for each module installed in the case. This information can be
displayed on the front panel.
Rack-Mounted Sample Gas Conditioning Systems
VS-3000 Series
Flow Rate Display:
A miniature mass flow meter is installed to monitor the flow rate of gas through
the instrument. The flow rate is displayed on the front panel and if the flow rate
deviates from a preset value an alarm will be displayed on the front panel and,
if the VA-PIO-01 board or other communication options are installed, will be
transmitted external to the instrument.
Stainless Steel Tubing with Swaglok Fittings
Stainless Steel Tubing and Swaglok Fittings can be provided as an option
when the instrument is initially delivered. This option cannot be easily added
at a later date. This option is not available for the CLD or O2 analyzer modules
at this time.
Separate Gas Inlet Fittings per Module:
In the standard instrument, gas flows to the three modules sequentially in
series. As an option HORIBA can make separate gas inlet connections for each
module with a common exhaust; however, the software is designed so that all
three modules will be in the zero calibration mode simultaneously and this
cannot be changed. The span calibration may be done separately.
Gas Connections on the Front Panel:
The gas connections can be moved from the rear of the case to the front panel
but if this is done then only two analyzer modules will fit into the standard
VA-3000 case.
HORIBA continues contributing
to the preservation of the global
environment through analysis
and measuring technology.
Please read the operation manual before using this product to assure safe and proper handling of the product.
G The contents of this catalog are subject to change without prior notice, and without any subsequent liability to this company.
G The color of the actual products may differ from the color pictured in this catalog due to printing limitations.
G It is strictly forbidden to copy the content of this catalog in part or in full.
G All brand names, product names and service names in this catalog are trademarks or registered trademarks of their respective companies.
http://www.horiba.com
G HORIBA, Ltd.
Head Office
Miyanohigashi, Kisshoin
Minami-ku, Kyoto, Japan
Phone: 81 (75) 313-8123
Fax: 81 (75) 321-5725
e-mail: info@horiba.co.jp
Tokyo Sales Office
1-7-8 Higashi-Kanda
Chiyoda-ku, Tokyo, Japan
Phone: 81 (3) 3861-8231
Fax: 81 (3) 3861-8259
Alarms recorded include:
Zero/ Span Calibration alarm, Cell Temperature and Chopper alarm for NDIR,
Detector Temperature alarm for CLD module.
G HORIBA INSTRUMENTS
Pte. LTD.
10 Ubi Crescent
#05-11/12, Ubi Techpark
Singapore 408564
Phone: 65 6745-8300
Fax: 65 6745-8155
G HORIBA EUROPE GmbH
Head Office
Hans-Mess-Str.6
D-61440 Oberursel/Ts.
Germany
Phone: 49 (6172) 1396-0
Fax: 49 (6172) 137385
Bulletin:HRE-2854C
G HORIBA INSTRUMENTS
INCORPORATED
Irvine Facility
17671 Armstrong Avenue
Irvine, CA 92614, U.S.A.
Phone: 1 (949) 250-4811
Fax: 1 (949) 250-0924
Leichlingen Facility
Julius-kronenberg Strasse
D-42799 Leichlingen
Germany
Phone: 49 (2175) 8978-0
Fax: 49 (2175) 8978-50
G HORIBA TRADING (SHANGHAI) CO., Ltd.
Beijing Office
Shanghai Office
Room 1701, United Plaza,
1468 Nanjing Rd. West,
Shanghai, 200040, China
Phone: 21-6289-6060
Fax: 21-6289-5553
G HORIBA GmbH
Kaplanstrasse 5
A-3430 Tulln,
Austria
Phone: 43 (2272) 65225
Fax: 43 (2272) 65230
G HORIBA KOREA Ltd.
112-6 Sogong-Dong
Choong-ku, Seoul, Korea
Room 1801, Capital Tower Beijing,
Tower 1 No.6Jia, Jianguomenwai Ave., Phone: 82 (2) 753-7911
Fax: 82 (2) 756-4972
Chaoyang District, Beijing,
100022 China
Phone: 10-8567-9966
Fax: 10-8567-9066
HORIBA CZECHIA
Organizachi slozka Praha
Petrohradska 13
CZ-101 00 Praha 10, Czech Republic
Phone: 420 (2) 717-464-80
Fax: 420 (2) 717-470-64
G HORIBA INSTRUMENTS
LIMITED
Kyoto Close
Summerhouse Road
Moulton Park, Northampton
NN3 6FL, U.K.
Phone: 44 (1604) 542500
Fax: 44 (1604) 542699
G HORIBA FRANCE
12, Avenue des Tropiques
91955 LES ULIS
France
Phone: 33 (1) 69-29-96-23
Fax: 33 (1) 69-29-95-77
Printed in Japan ZY-F(SK)33

"

IRAN INDUSTRY EXPO

The largest online Industrial exhibition in Iran

 عضویت ورود   ENGLISH


اگر مجموعه شما جزو صنایع مادر و معظم در فیلد پالایشگاه ، پتروشیمی ، حفاری ، نیروگاه ، معادن و فلزات ، خودروسازی ، تولید مواد غذایی و.... می باشد لطفا درخواست خود را بر روی سربرگ به فاکس 88206264 و یا ایمیل enquiry@iranindustryexpo.com بنام شرکت مهندسی و بازرگانی مشگاد ارسال فرمایید.
اگر مجموعه شما جزو بنگاه های متوسط و کوچک در فیلد تولید ، بازرگانی ، مشاوره ، پیمانکاری ، دانشگاه ، پژوهشگاه ، توزیع ، فروشگاهی وکارگاهی می باشد ، پس از عضویت و با پرداخت هزینه ( به ازای هر درخواست معادل 50 یورو ) از خدمات زیر برخوردار خواهید شد :
  • پاسخ به پرسش های فنی و دریافت مشاوره از سازنده ، دریافت کاتالوگ و اطلاعات تکمیلی
  • دريافت پرفورما از شرکت سازنده
  • اطلاع از زمان تحويل و قيمت خالص كالا
  • اطلاع از هزينه هاي حمل و ترخيص و کارمزد تا تحويل كالا به انبار شما در هر نقطه از كشور
  • دریافت پیش فاکتوررسمی ( ارزی و یا ریالی ) به روش کارمزدی
*صدور پیش فاکتور رسمی فقط به نام شرکتهای ثبت شده که دارای کد بازرگانی معتبر باشند انجام پذیر است. در صورتیکه در حین مکاتبه با شرکت سازنده مشخص شود که دارای نماینده انحصاری و یا شعبه در ایران بوده و یا به به هر دلیل شرکت سازنده از فروش کالا به بازار ایران استنکاف نماید ارایه این سرویس متوقف و وجه دریافتی به حساب کاربر عودت می شود

ادامه