SULFURCHROME SPECIFICATIONS
PERFORMANCE
Span drift
+/- 2% F.S.
Accuracy
+/- 2% F.S.
Repeatability
+/-2% F.S.
Sensitivity
Linearity
Response time
1% F.S.
+/- 2% F.S.
4 to 15 minutes, application dependent
ENVIRONMENT
Ambient temperature
Dimensions
Weight
0°C to 50°C (32° F to 122°F)
711 mm H x 1016 mm W x 406 mm D (28” H x 40” W x 16” D)
57 kg (125 lbs)
UTILITIES
Power &
consumption
Sample flow
Air requirements
Gas requirements
100-240 VAC, 50/60 Hz
600 watts
100 cc/min, 1 barg (0.21 SCFH, 15 psig)
37.7 L/min, 5.3 barg to 8 barg (80 scfh, 80 - 120 psig)
Helium: 20 cc/min, 5.3 to 6.7 barg (0.042 scfh, 80-100 psig)
Hydrogen: 80 cc/min, 4 to 5.3 barg (0.17 scfh, 60-80 psig)
COMMUNICATIONS
Digital Outputs
Digital Inputs
Analog Outputs
Relays
Modbus RS232, Modbus RS485
6 dry contact, 2 wet
4 x 4-20 mA, user scalable, user selectable loop or self powered
4 x SPDT relays, 8 amp @250 VAC
APPROVALS & CERTIFICATIONS
CSA General Pupose