8845A/8846A 6.5 Digit Precision Multimeters0 pages
11114-eng Rev. 02
8845A/8846A
6.5 Digit Precision Multimeters
Included Accessories
LCI Line Power Cord, TL71 Test Lead Set,
Spare Line Power fuse, Programmers
Manual/User Manual on CD-ROM, FVF-BASIC
FlukeView Forms Software Basic Version.
Ordering Information
Fluke 8845A 6.5 Digit Precision
Multimeter
Fluke 8845A/SU 6.5 Digit Precision
Multimeter (software + cable)
Fluke 8846A 6.5 Digit Precision
Multimeter
Fluke 8846A/SU 6.5 Digit Precision
Multimeter (software + cable)
Calibration & Service agreements
The Fluke 8845A and 8846A, 6.5 digit
precision multimeters have the precision
and versatility to handle your most
demanding measurements on the bench
or in a system.
Dual Display offers versatile graphical
capabilities: The 8845A and 8846A
features a unique graphical display that
can reveal signal quality issues like drift,
intermittent and stability by viewing
the measurement data as a real time
TrendPlot™, Histogram or Statistics
using the unique analyze mode.
Wide Measurement Ranges: Resistance
or current has been extended to cover
the widest range possible.
Perform 4-wire measurements easily
with two leads: Patented split terminal
jacks for 2x4 Ohms function allows you
to perform precise 4-wire measurements
with only two leads instead of four.
Optional Kelvin leads accessories are
available to enable you to establish a 4-
wire connection even in tight spaces.
Systems Capabilities: Both instruments
include an RS-232, IEEE-488 and Ethernet
interface as standard, with popular
DMM emulation modes makes systems
integration a simple task.
Software: Transfer data points from your
meter to your PC with the free copy of
FlukeView Forms Basic. To customize
your forms upgrade with FVF-UG.
* Accuracy =+/- (% of reading)
884X-case
Hard case
TL2X4W-TWZ
2x4 Wire Ohms Tweezer
Test Leads
TL2X4W-PT II
2x4 Wire Ohms Test
lead 2mm Probe Tip
884X-512M
USB Memory 512M
FVF-UG
FlukeView Forms
Software Upgrade
Size (HxWxD): 88 mm x 215 mm x 293 mm
Weight: 3.6 kg
One Year Warranty
Features
Specifications
Fluke 8846A
(Check the Fluke web for detailed specifications)
Recommended Accessories
Fluke 8845A
8845A 8846A
Function* Range Resolution Accuracy* (%) Range Resolution Accuracy* (%)
Voltage DC 1000 V 100 nV 0.0035 1000 V 100 nV 0.0024
Voltage AC (Freq 300 Hz) 750 V 100 nV 0.06 1000 V 100 nV 0.06
Resistance (2x4 Wire) 100 MÙ 100 ìÙ 0.01 1 GÙ 10 ìÙ 0.01
Current DC 10 A 100 pA 0.05 10 A 100 pA 0.05
Current AC (Freq. 3Hz-10kHz) 10 A 10 ìA 0.10 10 A 100 pA 0.10
Freq/Period 300 kHz 1 ìHz 0.01 1 MHz 1 ìHz 0.01
Capacitance - - - 1 nF to 0.1 F 1 pF 1
Temperature RTD - - - -200 to +600º 0.001º 0.06
True RMS
8845A 8846A
Display Dual VFD Dot Matrix
Resolution 6.5 Digits
Measurement Rate (Rdgs/s) 1000
Continuity / Diode Test Yes
Analytical Functions Statistics, Histogram, TrendPlot™, Limit Compare
Math Functions NULL, Min/Max, dB/dBm
USB Device Port – USB Memory Drive port
Real Time Clock – Yes
Interfaces RS232, IEEE-488.2, Ethernet
Programming Languages/
Emulation Modes
SCPI (IEEE-488.2), Agilent 34401A, Fluke 45
Safety Designed to comply with IEC 61010-12000-1, ANSI / ISA-S82.01-1994, CAN /
CSA-C22.2 No.1010.1-92 1000V CATI / 600V CATII
Precision and versatility for bench or
systems applications
Handle even the most demanding measurements with
high accuracy and 6.5 digit resolution
View results in Histogram mode to reveal stability or
noise problems in analog circuits
Use the built-in TrendPlot paperless chart recorder to
graphically identify the extent of drift and intermittent
events in analog circuits