BFM 20110 pages
for generator sets 13-64 kW|17 - 85 hp at 1500/1800 mirr1|rpm
for markets without emission regulation
• Oil-cooled 2- 3-and 4-cylinder natural-
ly aspirated in-line engines. 4-cylinder
engines also with turbocharging and
optional charge air cooling.
• Direct injection with single injection
pumps and optional electronic gover-
nor.
• Long oil change intervals of up to 1000
hours.
• Minimised running costs due to low
maintenance need and little wear.
• Low fuel consumption due to optimised
combustion.
• High reliability combined with durability.
No corrosion or cavitation due to oil
cooling and lubrication.
• Avery good load response ensures an
immediate power supply.
The DEUTZ Telco Engine
Technical data
Engine type
No. of cylinders
Bore/stroke
Displacement
Weight (incl. cooler and fan)
Governing standard1'
F2M2011 F3M2011 F4M2011 BF4M2011 BF4M2011C
mm | in 94/112 |3.7/4.4 94/112 |3.7/4.4 94/112 |3.7/4.4 94/112 |3.7/4.4 94/112 |3.7/4.4
11 cu in 1.6 |95 2.3 |142 3.1 |190 3.1 |190 3.1 |190
kg | lb 224 |494 265 |584 303 |667 304 |671 362 |798
G2 G2 G2 G2 G2
■1
50 Hz/1500min
Power
Continuous Power (COP)2'
Prime Power (PRP)3'
Limited Time Power (LTP)4'
Typical Generator Output COP
Typical Generator Output PRP
Typical Generator Output LTP
kW| hp
kW| hp
kW| hp
kVA
kVA
kVA
F2M2011 F3M2011 F4M2011 BF4M2011 BF4M2011C
11.8 |15.8
12.4 |16.6
13.0 |17.4
12
12
13
19.4 |26.0
20.4 |27.4
21.4 |28.7
20
21
22
27.9 |37.4
29.4 |39.4
30.9 |41.4
30
32
33
37.2 |49.9
39.2 |52.6
41.2 |55.3
40
42
44
50.6 |67.9
53.3 |71.5
56.1 |75.2
54
57
60
60 Hz/1800min-
Power
Continuous Power (COP)2'
Prime Power (PRPp~
Limited Time Power (LTP)4'
Typical Generator Output COP
Typical Generator Output PRP
Typical Generator Output LTP
kW| hp
kW| hp
kW| hp
kWe
kWe
kWe
F2M2011 F3M2011 F4M2011 BF4M2011 BF4M2011C
14.3 |19.2
15.0 |20.1
15.8 |21.2
11
12
13
22.1 |29.6
23.3 |31.2
24.5 |32.9
18
19
20
31.8 |42.6
33.5 |44.9
35.2 |47.2
27
29
30
1) According to ISO 8528-5.
2) Continuous Power: No time limitation, plus 10% additional power for governing purpose only.
3) Prime Power: Average power output £ 80%, no time limitation, plus 5% additional power for governing purpose only.
4) Limited Time Running Power: For up to 500 h/year, thereof a maximum of 300 h/year continuous running.
The data on this data sheet are for information purposes only and are not binding values. The data in the quotation is definitive.
42.8 |57.4
45.0 |60.3
47.3 |63.4
36
38
40
The engine company.
57.4 |77.0
60.4 |81.0
63.6 |85.3
48
51
53
A
DEUT;
"