Series 5000 Counter Current Packed Tower Scrubber Systems0 pages
SERIES 5000
COUNTER-CURRENT
PACKED TOWERS
CFM
400
1,500
2,400
3,400
4,600
6,000
7,600
9,400
11,400
13,600
15,900
18,500
21,100
24,100
27,200
30,500
34,000
37,700
41,500
45,600
50,000
A
6"
10"
l'-O"
l*-4"
l'-6"
l'-8"
2'-0"
2*-6"
2'-9"
3'0"
3'-3"
3'-6"
3'-9"
4'-0"
4'-3"
4'-6"
4'-9"
5'0"
5'-3"
5'-6"
5'-9"
l'-lO"
2'0"
2*-2"
2'-4"
2'-6"
2'-8"
2'-10"
3'-0"
3'-2"
3'-4"
3'-6"
3'-8"
3'-10"
C
6"
10"
l'-O"
l'-4"
l'-6"
r-8"
2*0"
2*-6"
2'-6"
3'0"
3*0"
3'-0"
3'-6"
3'-6"
3'-6"
4'0"
4*0"
4'-0"
4'-6"
4'-6"
4'-9"
D
l'-O"
2'-0"
2'-6"
3*0"
3'-6"
4'-0"
4'-6"
5'0"
5'-6"
6'0"
6'-6"
7'-0"
T-6"
8'-0"
8'-6"
9'-0"
9'-6"
lO'-O"
10'-6"
ll'-O"
ll'-6"
E
l'-9"
2'-6"
3'1"
3'-2"
3*-3"
3'-4"
3'-6"
3*-7"
3'-8"
3'-9"
3'-10"
3'-ll"
4'-0"
4'1"
4'-2"
4'-4"
4'-5"
4'-6"
4'-7"
4'-8"
4'-10"
F*
10'-0"
ll'-O"
12'0"
12'-6"
13'-2"
13'-7"
14'-6"
13'-8"
14'-3"
14'-7"
15*1"
15'-2"
15'-7"
16'1"
16'-6"
16'11"
17'-5"
17'-5"
17'-9"
18'1"
18'-6"
G*
r -9"
8'-8"
9'-7"
9*11"
10'-4"
10'-8"
ll'-5"
10'-6"
10'-11"
11 *-2"
ll'-6"
ll'-6"
ll'-9"
12*-1"
12'-4"
12'-8"
13'-0"
12*10"
13'-1"
13'-4"
13'-7"
Intermediate and larger sizes are available. Consult factory on specific requirements.
F* and G* dimensions based on a 4 foot packing depth and may vary depending on
application.
Bionomic counter-current packed towers are the ideal
solution to air pollution problems associated with the
removal of corrosive vapors, unwanted mists, noxious
and odoriferous gases.
By creating a counter-current flow between
contaminated gases and scrubbing liquid throughout
a high surface area packed bed, rapid and uniform
absorption of pollutants is achieved with maximum
efficiency.
Series 5000 towers are designed to accept a wide
variety of packings, mist eliminators and gas-
scrubber liquor distribution systems. This enables the
scrubbers to meet a full range of applications and gas
absorption requirements.
For specially troublesome low solubility gases,
scrubbers can be custom engineered to include extra
depth or multiple packed beds with intermediate step
chemical treatment.
Standard tower designs cover gas flow rates from 400
to 50,000 ACFM. Construction materials include
thermoplastics, fiberglass reinforced plastic, mild
steel, stainless steel, high nickel alloys, hastalloy and
corrosion resistant coatings and linings.
In situations where building codes limit the height of
rooftop structures, or where lower absorption ef-
ficiencies are acceptable, compact horizontal cross-
flow packed scrubbers are available.
3
"