TST/DMT Interface to QL II0 pages
TST/DMT Interface
to QL II
The TST/DMT Interface is for those clients who wish to use the
Crane Torque Switch and Displacement Measuring Transducers*
with the Teledyne QUIKLOOK II Motor Operated Valve Diagnostic
System.
Features
• Uses standard QUIKLOOK excitation power
• Self-contained solution
• Accuracy 1% of Reading
The TST/DMT Interface (P/N 160066), together with included cable
(P/N 160067), may be used on any QLII channel. There are two
receptacles on the Interface box; connect the 7-pin Lemo plug on
the Interface cable to the 7-pin receptacle, the QLII input cable
plug to the 4-pin Lemo, and the MS connector to the transducer.
To configure the QLII channel enter the original transducer
sensitivity divided by the attenuation factor noted on the TST/DMT
Interface (typically 0.5) and set the channel type for voltage.
* The Torque Switch Transducer (TST) and Displacement Measuring
Transducer are products of the Crane Nuclear Company.
TELEDYNE TEST SERVICES
513 Mill Street, Marion, MA 02738 USA
Tel +1 508.748.0103 • Fax +1 508.748.1093 • E-mail: rwmasson@teledyne.com
www.ValveTest.com
Specifications subject to change without notice. 12/1/10. ©2010 TELEDYNE TEST SERVICES, Inc.
Other products and company names mentioned herein may be trademarks and/or registered trademarks.