Model 2390 pages
800-257-3872
159 Swanson Rd., Boxborough, MA/Telephone: 978-263-1400/Fax: 978-264-0292
U.S. Patent nos. 4093915
Model 239/C239
High Accuracy/Low Range Pressure
Differential Pressure: 0 - ±0.25 in. W.C. to 0 -10 psid
Pressure Media Air or Other Gases
Applications
œ HVAC Control
œ Leak Detection
œ Environmental Testing
œ Medical Instrumentation
œ Energy Management
œ Clean Rooms
Features
¡ ± 0.14% FS Accuracy
¡ Fast Warm-up
¡ Low Thermal Effects
¡ Fast Response,
<10 milliseconds
¡ Withstands High
Overpressure
¡ Meets CE Conformance
Standards
Visit Setra Online:
http://www.setra.com
Setra’s unique electronic circuit. The Model
239 provides a high level voltage output. The
C239 provides a 4-20 mA current output. High
positive overpressure protection is achieved
by the sensor electrode acting as a stop for the
diaphragm. The high level output signals,
excellent long term stability and fast dynamic
response make these transducers ideal for a
wide range of industrial, laboratory and
aerospace applications.
Pressure Range Proof Pressure
Unidirectional Positive Negative
Pressure
0 to 0.5 in. WC 5 PSI 2.5 in. WC
0 to 1 in. WC 7 PSI 5 in. WC
0 to 2.5 in. WC 10 PSI 12.5 in. WC
0 to 5 in. WC 20 PSI 25 in. WC
0 to 15 in. WC 50 PSI 75 in. WC
0 to 30 in. WC 50 PSI 150 in. WC
0 to 5 PSID 75 PSI 25 PSI
0 to 10 PSID 100 PSI 50 PSI
Bidirectional Pressure
0 to ± 0.25 in. WC 5 PSI 2.5 in. WC
0 to ± 0.5 in. WC 7 PSI 5 in. WC
0 to ± 1 in. WC 10 PSI 12.5 in. WC
0 to ± 2.5 in. WC 20 PSI 25 in. WC
0 to ± 7.5 in. WC 50 PSI 75 in. WC
0 to ± 15 in. WC 50 PSI 150 in. WC
0 to ± 2.5 PSID 75 PSI 25 PSI
0 to ± 5 PSID 100 PSI 50 PSI
Full Scale Ranges
Setra’s Model 239 series of pressure
transducers are specifically designed for
very low pressure applications that
require high accuracy.
Setra’s variable capacitance sensor is designed
to be simple and reliable. A stainless steel
diaphragm and an insulated electrode form a
variable capacitor. As pressure increases or
decreases, the capacitance changes. This
change in capacitance is detected and
converted to a linear D.C. electric signal by
NOTE: Setra adheres to strict quality standards including
ISO 9001 and ANSI-Z540-1. The calibration of this product is
NIST traceable.
When it comes to a product to rely
on - choose the Model 239. When it
comes to a company to trustchoose
Setra.
Certified
ISO 9001