LOW PROFILE COMPRESSION LOAD CELL0 pages
LOW PROFILE COMPRESSION LOAD CELL
5950
Load cell combining high capacity, low design and cost effective solution.
Features
Model 5950 - 2 t
- Stainless steel
- Protection IP 67
- Low design
- Cost effective solution
- Sturdy design
- Easy to install
- Whole range of mounting kits available
- Available options (non exhaustive list):
o ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80°C Da
o high service temperature (up to 150 °C)
Applications
The SENSY's load cell 5950 is perfectly designed to the following applications :
- Silos, tanks or hoppers weighing
- Reactors weighing
- Industrial force measurement where space is limited
Capacities
5950 : (0.3) - (0.5) - (0.75) - (1) - (1.5) - 2 - 3 - 5 - 7.5 - 10 - (15) - 20 t
Specifications
0.25
Accuracy class
0.1
1000 d
-
Combined error
< ± 0.25
< ± 0.10
% F.S.
Linearity error
< ± 0.25
< ± 0.10
% F.S.
Repeatability error
< ± 0.1
< ± 0.03
% F.S.
Creep error over 30 min.
< ± 0.1
< ± 0.06
% F.S.
Zero shift after loading
< ± 0.025
< ± 0.015
% F.S.
Reference temperature
23
23
°C
Nominal temperature range
-10...+45
-10...+45
°C
Service temperature range
-30...+70
-30...+70
°C
Storage temperature range
-50...+85
-50...+85
°C
Temperature coefficient of the sensitivity
< ± 0.05
< ± 0.05
% F.S./10°C
Temperature coefficient of zero signal
< ± 0.035
< ± 0.035
% F.S./10°C
Zero balance
± 0.02
± 0.02
mV/V
Sensitivity tolerance
< ± 0.3
< ± 0.3
%
Insulation resistance (50V)
> 5000
> 5000
Megaohm
10
10
VDC
3..12
3..12
VDC
1.5
1.5
mV/V
Reference excitation voltage
Nominal range of excitation voltage
Nominal sensitivity
Safe load limit
150
150
% F.S.
Breaking load
>300
>300
% F.S.
10
10
% F.S.
Static lateral force limit
Permissible dynamic loading
40
40
% F.S.
Input resistance
702 ± 2
702 ± 2
Ohm
Output resistance
702 ± 2
702 ± 2
Ohm
F.S.: full scale - Specifications subject to change without notice
FP-5950_EN.pdf
rev. : 23/05/2014
"